Design and performance of spinal fixation pedicle screw system.
نویسندگان
چکیده
Pedicle screw-rod bilateral constructions are extensively used in spinal fixation. In this study, the common cause for failure of bilateral constructions has been determined to be the high stress concentration at the rod-setscrew interface. In order to overcome this problem, a design modification has been made by using a supplementary part (shoe) between rod and setscrew. Performance comparison of the conventional design and modified design has been done by conducting static tests. Design modification has resulted in 11%, 27%, 42% and 31% improvements in axial gripping capacity, torsional gripping capacity, flexion/extension resistance and subassembly compression strength, respectively. The most outstanding achievement has been obtained in the fatigue life, which was extended by almost three times.
منابع مشابه
Possible usage of cannulated pedicle screws without cement augmentation
BACKGROUND: The use of pedicle screws is becoming increasingly popular for spinal surgery practice as the technology advances. Screw pullout due to bone quality and loading conditions is one of the most common problems observed after pedicle screw fixation. Several solutions were studied to prevent screw pullout. These can be investigated under three main categories: screw design, expandable sc...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملMonitoring the quality of robot-assisted pedicle screw fixation in the lumbar spine by using a cumulative summation test.
STUDY DESIGN Prospective randomized controlled trial. OBJECTIVE The aim of this study was to monitor the quality control of robot-assisted pedicle screw fixation accuracy by using a cumulative summation (CUSUM) test at the initial stage of its application. SUMMARY OF BACKGROUND DATA Although robot-assisted pedicle screw fixation reduces screw misplacement rates and provides critical support...
متن کاملCervical Pedicle Screw Placement in Sawbone Models and Unstable Cervical Traumatic Lesions by Using Para-Articular Mini-Laminotomy: A Novice Neurosurgeon’s Experience
Cervical pedicle screw has been shown to provide stronger fixation than other methods. Due to these virtue of biomechanical characteristic, pedicle screw fixation can be used in a wide range of cervical spinal disorders, and excellent clinical results have been reported. However, this procedure is technically demanding because of the great variation in pedicle dimension and angulations between ...
متن کاملشکست وسایل تثبیت ستون فقرات
This was a retrospective review of a consecutive series of patients with spinal disease in year 2000, who underwent posterior fusion and instrumentation with Harrington distraction and Cotrel-Dobousset system to evaluate causes of hardware failure. Many cases of clinical failure has been observed in spinal instrumentation used in spinal disorder like spondylolisthesis, fractures, deformities, …...
متن کاملMini-open (Less Invasive) tLIF procedure with unilateral pedicle Screw Fixation
Generally, bilateral pedicle screw fixation after Minimal Invasive (MIS) TLIF is accepted as a standard procedure for treating symptomatic spinal pathologies, such as degenerative spinal stenosis, spondylolisthesis, recurrent disc herniation, postlaminectomy instability, and deformity (10). Some authors have recently demonstrated that unilateral pedicle screw fixation is as effective for spinal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 226 1 شماره
صفحات -
تاریخ انتشار 2012