SIMA: Simultaneous Multiple Alignment of LC/MS Peak Lists
نویسندگان
چکیده
MOTIVATION Alignment of multiple liquid chromatography/mass spectrometry (LC/MS) experiments is a necessity today, which arises from the need for biological and technical repeats. Due to limits in sampling frequency and poor reproducibility of retention times, current LC systems suffer from missing observations and non-linear distortions of the retention times across runs. Existing approaches for peak correspondence estimation focus almost exclusively on solving the pairwise alignment problem, yielding straightforward but suboptimal results for multiple alignment problems. RESULTS We propose SIMA, a novel automated procedure for alignment of peak lists from multiple LC/MS runs. SIMA combines hierarchical pairwise correspondence estimation with simultaneous alignment and global retention time correction. It employs a tailored multidimensional kernel function and a procedure based on maximum likelihood estimation to find the retention time distortion function that best fits the observed data. SIMA does not require a dedicated reference spectrum, is robust with regard to outliers, needs only two intuitive parameters and naturally incorporates incomplete correspondence information. In a comparison with seven alternative methods on four different datasets, we show that SIMA yields competitive and superior performance on real-world data. AVAILABILITY A C++ implementation of the SIMA algorithm is available from http://hci.iwr.uni-heidelberg.de/MIP/Software.
منابع مشابه
Method development for simultaneous determination of 41 pesticides in rice using LC-MS/MS technique and its application for the analysis of 60 rice samples collected from Tehran market
For the first time, a multi-residue methodfor simultaneous determination of 41LC-amenable pesticides in rice, belonging to different chemical classes has been developed in Iran by LC-MS/MS. The pesticides were analyzed simultaneously in a single run using positive electrospray ionization with multiple reaction monitoring (MRM) after extraction with slightly modified QuEChERS method. The calibra...
متن کاملMethod development for simultaneous determination of 41 pesticides in rice using LC-MS/MS technique and its application for the analysis of 60 rice samples collected from Tehran market
For the first time, a multi-residue methodfor simultaneous determination of 41LC-amenable pesticides in rice, belonging to different chemical classes has been developed in Iran by LC-MS/MS. The pesticides were analyzed simultaneously in a single run using positive electrospray ionization with multiple reaction monitoring (MRM) after extraction with slightly modified QuEChERS method. The calibra...
متن کاملGraph-based peak alignment algorithms for multiple liquid chromatography-mass spectrometry datasets
UNLABELLED Liquid chromatography coupled to mass spectrometry (LC-MS) is the dominant technological platform for proteomics. An LC-MS analysis of a complex biological sample can be visualized as a 'map' of which the positional coordinates are the mass-to-charge ratio (m/z) and chromatographic retention time (RT) of the chemical species profiled. Label-free quantitative proteomics requires the a...
متن کاملMulti-profile Bayesian alignment model for LC-MS data analysis with integration of internal standards
MOTIVATION Liquid chromatography-mass spectrometry (LC-MS) has been widely used for profiling expression levels of biomolecules in various '-omic' studies including proteomics, metabolomics and glycomics. Appropriate LC-MS data preprocessing steps are needed to detect true differences between biological groups. Retention time (RT) alignment, which is required to ensure that ion intensity measur...
متن کاملA Novel Two-Stage Alignment Method for Liquid Chromatography Mass Spectrometry-Based Metabolomics
We report a novel two-stage alignment algorithm that contains full alignment and partial alignment, for the analysis of LC-MS based metabolomics data. The purpose of full alignment is to detect landmark peaks that present in all peak lists to be aligned. These peaks were first selected based on m/z value and isotopic peak profile matching. After removing peaks with large Euclidian distance of r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bioinformatics
دوره 27 7 شماره
صفحات -
تاریخ انتشار 2011