Buckling resistance, bending stiffness, and torsional resistance of various instruments for canal exploration and glide path preparation

نویسندگان

  • Sang-Won Kwak
  • Jung-Hong Ha
  • WooCheol Lee
  • Sung-Kyo Kim
  • Hyeon-Cheol Kim
چکیده

OBJECTIVES This study compared the mechanical properties of various instruments for canal exploration and glide-path preparations. MATERIALS AND METHODS The buckling resistance, bending stiffness, ultimate torsional strength, and fracture angle under torsional load were compared for C+ file (CP, Dentsply Maillefer), M access K-file (MA, Dentsply Maillefer), Mani K-file (MN, Mani), and NiTiFlex K-file (NT, Dentsply Maillefer). The files of ISO size #15 and a shaft length of 25 mm were selected. For measuring buckling resistance (n = 10), the files were loaded in the axial direction of the shaft, and the maximum load was measured during the files' deflection. The files (n = 10) were fixed at 3-mm from the tip and then bent 45° with respect to their long axis, while the bending force was recorded by a load cell. For measuring the torsional properties, the files (n = 10) were also fixed at 3-mm, and clockwise rotations (2-rpm) were applied to the files in a straight state. The torsional load and the distortion angle were recorded until the files succumbed to the torque. RESULTS The CP was shown to require the highest load to buckle and bend the files, and the NT showed the least. While MA and MN showed similar buckling resistances, MN showed higher bending stiffness than MA. The NT had the lowest bending stiffness and ultimate torsional strength (p < 0.05). CONCLUSIONS The tested instruments showed different mechanical properties depending on the evaluated parameters. CP and NT files were revealed to be the stiffest and the most flexible instruments, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PathFileTM: A New Rotary Nickel-Titanium Instrument for Mechanical Glide Path and Preflaring

NiTi instrument separation is a serious concern in endodontic therapy. The analysis of NiTi files after torsional fracture reveals that the majority of torsional separations occur in the last mm. of the files and in the files with lower taper and/ or diameter. Consequentely, the tip of the smaller files presents the higher risk of torsional fracture and should be protected using low torque moto...

متن کامل

PathFiles: A New Rotary Nickel-Titanium Instrument for Mechanical Glide Path and Preflaring

NiTi instrument separation is a serious concern in endodontic therapy. The analysis of NiTi files after torsional fracture reveals that the majority of torsional separations occur in the last mm. of the files and in the files with lower taper and/ or diameter. Consequentely, the tip of the smaller files presents the higher risk of torsional fracture and should be protected using low torque moto...

متن کامل

The effect of discrete lateral and torsional bracings stiffness on the elastic lateral-torsional buckling of mono-symmetric I beam, under the concentrated moment

When the out-of-plane stiffness of a beam is remarkably lower than the in-plane stiffness, the lateral-torsional buckling occurs. In this study, the behavior of mono-symmetric I-beams with discrete torsional and lateral bracings under the concentrated moment is investigated using the finite element analyses. Then, based on the numerical analyses, equation for the stiffness requirement is propos...

متن کامل

The influence of glide path preparation on the failure rate of WaveOne reciprocating instruments.

INTRODUCTION The aim of this study was to determine the influence of two different glide path preparation methods on the fracture rate of the Primary 25/08 WaveOne reciprocating instrument. Preparation times for different glide path methods and total time for root canal preparation, with and without prior glide path preparation, were also calculated. MATERIALS AND METHODS ISO 15, 0.02 taper E...

متن کامل

Effectiveness of a manual glide path on the preparation of curved root canals by using Mtwo rotary instruments.

INTRODUCTION Nickel-titanium rotary instruments reduce procedural errors and the time required to finish root canal preparation. The goal of this study was to evaluate the effectiveness of a manual glide path on the preparation of curved root canals with Mtwo rotary system. METHODS Forty buccal root canals with angles of curvature between 25 to 76 degrees were randomly divided into 4 groups (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 39  شماره 

صفحات  -

تاریخ انتشار 2014