Accuracy of routine intraocular lens power calculation in a district general hospital.

نویسندگان

  • P T Gregory
  • R M Esbester
  • D L Boase
چکیده

To assess the accuracy of routine preoperative biometry we reviewed all cases of extracapsular cataract extraction with posterior chamber implant performed at Queen Alexandra Hospital in 1985. Of 471 eyes included in the survey 67.9% were within 1.0 D of the expected refraction and 90.7% within 2.0 D. Factors influencing accuracy are discussed. The necessity of routine preoperative biometry is emphasised.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

Intraocular Lens Power Calculation after Corneal Refractive Surgery

PURPOSE To determine the accuracy of a method of calculating intraocular lens (IOL) power after corneal refractive surgery. SETTING Department of Ophthalmology, Hospital de Gipuzkoa, San Sebastián, Spain. METHODS The SRK/T formula was modified to use the pre refractive surgery K-value (Kpre) for the effective lens position (ELP) calculation and the post refractive surgery K-value (Kpost) fo...

متن کامل

Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator

BACKGROUND Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month ...

متن کامل

Accuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation

PURPOSE To investigate the accuracy of a new optical biometer for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery. METHODS Consecutive eyes of patients undergoing cataract surgery with the same IOL model were enrolled in a prospective cohort study. Axial length (AL) and corneal power were measured with an optical biometer based on optical low-coherence interferome...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 73 1  شماره 

صفحات  -

تاریخ انتشار 1989