Ten-year evaluation of cementless Buechel-Pappas meniscal bearing total ankle replacement.

نویسندگان

  • Frederick F Buechel
  • Frederick F Buechel
  • Michael J Pappas
چکیده

A porous-coated, cementless, congruent-contact, three-piece, meniscal-bearing total ankle replacement was developed and used clinically over a 2- to 10-year period for patients with disabling ankle arthritis. Polished titanium-nitride ceramic-coated Ti6Al4V tibial and talar components with a deep-sulcus trochlear groove and two lateral fixation fins for the talar onlay component were used. The ultra-high-molecular-weight polyethylene (UHMWPe) meniscal bearing congruently conformed to the flat upper tibial component surface and the deep sulcus and cylindrical geometry of the lower talar component surface. Fifty deep-sulcus (Buechel-Pappas) total ankle replacements were implanted in 49 patients. Diagnoses were 8 osteoarthritis (16%), 7 rheumatoid arthritis (14%), 2 avascular necrosis (4%), and 33 post-traumatic arthritis (66%). Ages ranged from 26 to 71 years (mean 49 years). Clinical results using a strict ankle scoring system demonstrated good/excellent results in 88% of cases. Postoperative ankle motion ranged from 12 degrees to 46 degrees total arc (mean 28 degrees), which was similar to the preoperative motion. Revision for malalignment was necessary in two cases (4%). Mechanical complications included one case of meniscal bearing wear (2%) in a patient with post-traumatic arthritis with component malalignment and one case of talar component subsidence (2%) in a patient with avascular necrosis of the talus. No tibial component loosening was seen. Cumulative survivorship using an end point of revision of any component for any reason was 93.5% at 10 years (confidence interval 61-100%).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Twenty-year evaluation of cementless mobile-bearing total ankle replacements.

Two consecutive series of patients who had cementless, porous-coated, congruent-contact, mobile-bearing total ankle replacements were evaluated during a 20-year interval using the New Jersey Orthopaedic Hospital ankle scoring scale to determine clinical outcome and overall implant survivorship with revision as an end point. The initial series of 38 patients (40 ankle replacements) using a shall...

متن کامل

A randomised, controlled trial of two mobile-bearing total ankle replacements.

We describe the results of a randomised, prospective study of 200 ankle replacements carried out between March 2000 and July 2003 at a single centre to compare the Buechel-Pappas (BP) and the Scandinavian Total Ankle Replacement (STAR) implant with a minimum follow-up of 36 months. The two prostheses were similar in design consisting of three components with a meniscal polyethylene bearing whic...

متن کامل

Cementless meniscal bearing knee arthroplasty: 7- to 12-year outcome analysis.

1. Rotational mobility of a widely used rotating platform total knee replacement. Iowa Orthop J, 2001. 21: p. 90. 2. Multi-contact-surface finite element model of a widely used rotating platform total knee. Polyethylene wear in meniscal knee replacement. A one to nine-year retrieval analysis of the Oxford knee.Unicompartmental "Lotus" knee prosthesis. Analysis of the results of a series of 142 ...

متن کامل

Simulation of polyethylene wear in ankle joint prostheses.

The performance of total ankle replacements (TARs) have not been comparable to those of the other major joints of the lower extremity. The aim of this work was to develop a new simulator test to compare the wear of a new mobile bearing TAR (Mobility) with one with a good clinical history, the Buechel Pappas, using kinematic inputs derived from the literature. The wear rate for the Mobility comp...

متن کامل

Two- to 12-year evaluation of cementless Buechel-Pappas total hip arthroplasty.

A unique, straight-stemmed, proximally porous-coated, modular hip arthroplasty system, coated with thin-film (5- to 9-microm), titanium-nitride ceramic, was used clinically in 130 hip arthroplasties in 117 patients who were followed over a 2- to 12-year interval (mean, 6.45 years). Harris Hip Scores demonstrated 82.3% excellent, 15.4% good, 2.3% fair, and 0% poor results. Thigh pain that limite...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Foot & ankle international

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2003