Short paper EVect of the number of peak expiratory flow readings per day on the estimation of diurnal variation
نویسنده
چکیده
Background—The number of peak expiratory flow (PEF) readings required per day to assess diurnal variation accurately is not known; published studies have used between two and seven PEF readings per day. This study compares the diurnal variation calculated using 2–10 PEF readings per day. Methods—All days with 10 readings were selected from a database of PEF records. For each day, diurnal variations calculated using 2–9 of the readings available were compared with that calculated using the full 10 PEF readings. Diurnal variation calculated using all 10 readings was taken as the true diurnal variation. When less than 10 readings were used the readings were evenly spaced over waking hours. Diurnal variation was calculated as maximum —minimum/predicted. Results—Two hundred and 25 days with 10 readings per day were selected from PEF records provided by 63 individuals. When only two PEF readings per day were used, the limits of agreement suggested a possible underestimate of true diurnal variation, calculated using all 10 readings, of 1.23–15.10%. The possible underestimate fell to 0.27–3.96% when calculated using four evenly spaced readings. Analysis of the timing of the highest PEF reading of the day was undertaken for rest and work days. This showed a mean (SD) timing of 13:56 (4:56 hours) for rest days and 11:47 (5:59 hours) for work days. Conclusions—Clinicallysignificantunderestimates of true diurnal variation may be seen when only small numbers of PEF readings per day are used in its calculation. At and above four readings the results suggest that the underestimate becomes increasingly insignificant in terms of the diagnosis and treatment of asthma. Analysis of the timing of the highest PEF reading of the day showed a wide variation, precluding the ability to capture the true diurnal variation with just two or three carefully timed PEF readings per day. The authors suggests that at least four readings per day should be performed, evenly spaced during waking hours, to obtain an accurate assessment of diurnal variation in PEF. (Thorax 1998;53:790–792)
منابع مشابه
Peak Expiratory Flow Rate in Healthy Children from Tehran
Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines. Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...
متن کاملبررسی تاثیر 1،6 هگزامتیلن دی ایزوسیا نات بر نتایج تست پیک فلومتری در کارگران کارگاههای رنگ کاری اتومبیل شهر اصفهان
Abstract Background & Aims: Hexamethylene diisocyanate is an aliphatic isocyanate and car painters are exposed to it. One of the most important disorders is occupational asthma. The aim of this study was to survey the effect of 1, 6 hexamethylene diisocyanate on the peak expiratory flow test to car painters in Isfahan. Materials & Methods: In this descriptive and a cross-sectional study the f...
متن کاملDiurnal variation in peak expiratory flow rate among workers exposed to toluene diisocyanate in the polyurethane foam manufacturing industry.
The diurnal variation in peak expiratory flow rate (PEFR) was studied in 26 mixers from eight factories making polyurethane foam, who were exposed to toluene diisocyanate (TDI), and 26 unexposed controls matched for age, race, and smoking. They were all men. The mean diurnal variation in PEFR of the mixers was 6.2%, which was significantly higher than the 4.3% for controls. Six mixers had a diu...
متن کاملPeak expiratory flow analysis in workers exposed to detergent enzymes.
AIMS To study serial peak expiratory flow (PEF) responses in a group of symptomatic detergent enzyme-exposed workers. METHODS Workers were recruited from a biological detergent formulating and packaging company. Those with occupational asthma symptoms and/or specific IgE to a detergent enzyme were asked to complete 2 hourly PEF measurements for 4 weeks. Outputs from the Oasys program (Oasys s...
متن کاملاستفاده از مدل دبیهای آستانه جهت بررسی تغییرات فصلی جریانهای کم (مطالعه موردی رودخانه هلیل رود)
Low flow estimation and its characteristics play an important role in hydrologic studies. However, some low flow events are ignored compared with the lowest annual low flow that may have high risk. These events are taken into consideration by the use of partial duration or peak over threshold models. In this study, a 7-day low flow was applied for frequency distribution and threshold, and the l...
متن کامل