The effect of set-up uncertainties, contour changes, and tissue inhomogeneities on target dose-volume histograms.

نویسندگان

  • B C John Cho
  • Marcel van Herk
  • Ben J Mijnheer
  • Harry Bartelink
چکیده

Understanding set-up uncertainty effects on dose distributions is an important clinical problem but difficult to model accurately due to their dependence on tissue inhomogeneities and changes in the surface contour (i.e., variant effects). The aims are: (1) to evaluate and quantify the invariant and variant effects of set-up uncertainties, contour changes and tissue inhomogeneities on target dose-volume histograms (DVHs); (2) to propose a method to interpolate (variant) DVHs. We present a lung cancer patient to estimate the significance of set-up uncertainties, contour changes and tissue inhomogeneities in target DVHs. Differential DVHs are calculated for 15 displacement errors (with respect to the isocenter) using (1) an invariant shift of the dose distribution at the isocenter, (2) a full variant calculation, and (3) a B-spline interpolation applied to sparsely sampled variant DVHs. The collapsed cone algorithm was used for all dose calculations. Dosimetric differences are quantified with the root mean square (RMS) deviation and the equivalent uniform dose (EUD). To determine set-up uncertainty effects, weighted mean EUDs, assuming normally distributed displacement errors, are used. The maximum absolute difference and RMS deviation in the integral DVHs' relative dose between (1) the invariant and calculated curves are 65.2% and 5.8% and (2) the interpolated and calculated curves are 16.9% and 2.5%. Similarly, the maximum absolute difference and RMS deviation in mean EUD as a function of the set-up uncertainty's standard deviation between (1) the invariant and calculated curves are 0.02 and 0.01 Gy; and (2) the interpolated and calculated curves are 0.01 and 0.006 Gy. Since a "worst-case" example is selected, we conclude that, in the majority of clinical cases, the variant effects of contour changes, tissue inhomogeneities and set-up uncertainties on EUD are negligible. Interpolation is a valid, efficient method to approximate DVHs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی صحیح بودن مقدار اشعه داده شده در پرتودرمانی سرطان پستان با ترمولومینسانس دوزیمتری

In vivo dosimetry seems an appropriate method for quality assurance in radiotherapy with CO-60, which can be considered as a routine program in radiotherapy centers. In this study, entrance and exit dose in tangential fields were measured in phantom for 30 breast cancer patients by using TLD in radiotherapy section of Imam Khomeini Hospital. TLD crystals were calibrated against SSDL (Secondary...

متن کامل

Evaluation of the effect of dental filling material on IMRT treatment planning in patient with nasopharyngeal cancer

Introduction: Presence of dental filling material (DFM) such as amalgam in treatment patient with nasopharyngeal cancer (NPC) is common. Streaking artifact Arising from this high density material in computed tomography (scan), may lead to perturbation in dose calculation and dose delivery. Widespread performance of intensity-modulated radiotherapy (IMRT) for NPC using anterior...

متن کامل

Effect of replacing cochlea contour with inner ear contour on cochlea dose-volume calculations in conventional 2 dimensional and conformal 3 dimensional radiotherapy of brain

Introduction: Sensorineural hearing loss (SNHL) is one of the possible complications of radiotherapy treatment of brain tumors. The auditory system of patients with brain tumors often is placed inside of radiation field and receives a significant amount of radiation dose resulting in hearing loss. The purpose of this study was to compare contouring and delivery dose to cochlea...

متن کامل

The effect of Rectal Retractor, a rectal protector on rectal dose in radical prostate radiotherapy

Introduction: The close proximity of the rectum tissue to the prostate gland results in rectal toxicity during prostate radiotherapy. Rectal Retractor (RR) is a rectal displacement technique that inserts into the rectum, as a result, the lateral and dorsal part of the rectal wall push away from high dose areas. The aim of this study was to investigate the dosimetric consequence...

متن کامل

Evaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 29 10  شماره 

صفحات  -

تاریخ انتشار 2002