A field evaluation of five on-site drug-testing devices.
نویسندگان
چکیده
A field study was performed at two police agencies to evaluate the utility and accuracy of five on-site urine analysis drug-testing devices when used to test driving under the influence (DUI) arrestees. The devices evaluated were AccuSign, Rapid Drug Screen, TesTcup-5, TesTstik, and Triage. Standard workplace screening cut-off concentrations were used and samples were tested for marijuana, cocaine and metabolites, amphetamine(s), opiates, and PCP (except opiates 300 ng/mL). Four-hundred arrestees were recruited at each site, informed consent was obtained, and urine specimens were collected from each subject for analysis. Police officers conducted the testing with one device, and trained technicians performed testing with the other four devices. The device used by the officers was rotated. All positive and 5% of the negative samples were confirmed in a laboratory using mass spectrometry. Laboratory cut-off concentrations were 4 ng/mL for carboxy-THC; 50 ng/mL for benzoylecgonine; 100 ng/mL for amphetamines; 50 ng/mL for opiates; and 5 ng/mL for PCP. Approximately one-third (36%) of the subjects tested positive for at least one drug. No randomly selected sample, that tested negative on the devices, tested positive at the laboratory. Based on 800 specimens, the false-negative rate for each device was < 1% for all drug classes. A false positive was defined as testing positive with the device, but the specimen did not contain detectable drug, given the study reporting criteria. For marijuana, benzoylecgonine, and opiates, all devices had < or = 0.25% false-positive rates. For PCP, the false-positive rates were all < or = 1.5%. For amphetamine(s), the false-positive rates were all < or = 1.75%. These rates were adjusted because study confirmation batteries included methylenedioxyamphetamine, methylenedioxymethamphetamine (MDMA), additional over-the-counter sympathomimetic amines, hydromorphone, and hydrocodone. Without the expanded confirmation battery, false-positive rates approached 4% (Triage) for amphetamines and were > or = 2.25% for opiates. Fifty to 90% of the positive amphetamine(s) samples contained MDMA. A similar percentage of the opiate-positive samples contained hydromorphone or hydrocodone. When additional drugs were included in the confirmation testing, it was concluded that the on-site urine analysis drug-testing results were useful in DUI investigations.
منابع مشابه
Field effect transistor nanobiosensors: State-of-the-art and key challenges as point of care testing devices
The existing health care systems focus on treating diseases rather than preventing them. Patients are generally not tested unless physiological symptoms are appeared. When they do get tested, the results often take several days and can be inconclusive if the disease is at an early stage. In order to facilitate the diagnostics process and make tests more readily available for patients, the conce...
متن کاملEvaluation of the Interference of the Microwave Radiation Emitted from GSM Mobile Phones on the Performance of Cell Counters
Abstract Background and Objectives: Incidents related to electromagnetic interference with medical devices have been reported over the past decades. It has also been indicated that the microwave radiation emitted from mobile phones interferes with the operation of medical devices therefore, this study aimed at testing the interference by GSM mobile phones with cell counters. Material and Method...
متن کاملUse of on-site testing for drugs of abuse.
BACKGROUND There is currently a profusion of near-patient testing devices that have been specifically targeted at drug dependency units and clinics. Some of these devices have been shown to produce accurate results. However, some devices suffer from inappropriate labeling, which together with the subjective interpretation of poorly defined reaction end-point markers, leads to misinterpretation ...
متن کاملEvaluation of performance quality of SPECT camera in Shariati Hospital of Tehran University of Medical Sciences [Persian]
In nuclear medicine, there are two methods of imaging, planar and tomography. Single photon emission computerized tomography (SPECT) shows better image details and therefore is influenced more by image parameters such as resolution, uniformity, sensitivity, etc. Manufacturers provide customers with data which are obtained by complicated and sometimes secret methods. Marketing companies te...
متن کاملNanomedicine – The role of newer drug delivery technologies in cancer
Nanotechnology has slowly but steadily revolutionized the diagnosis, imaging and treatment of cancer. Detecting cancer at earliest stages, locating the tumor at different areas in the body and specific delivery of the drugs to malignant cells including surgically inaccessible tumors are the core areas of medical and pharmaceutical research across the world. In this endeavour, Nanodevices have e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of analytical toxicology
دوره 26 7 شماره
صفحات -
تاریخ انتشار 2002