Studies of potential-dependent metallothionein adsorptions using a low-volume electrochemical quartz crystal microbalance flow cell

نویسندگان

  • Alejandro L. Briseno
  • Fayi Song
  • Alfred J. Baca
  • Feimeng Zhou
چکیده

Adsorptions of metallothioneins (MTs) onto thin mercury films (TMFs) at potentials more negative or positive than the point of zero charge (pzc) of mercury were quantified for the first time, using a novel electrochemical quartz crystal microbalance (EQCM) flow cell in conjunction with a simple flow-injection system (FI-EQCM). The EQCM flow cell has a low internal volume (ca. 50 l) designed for the investigation of biomolecular attachment to surfaces. Such a cell facilitates in-situ gravimetric measurements of MT adsorption processes at different potentials. The amount of the MT adsorption at −0.9 V, a potential more negative than the pzc of the TMF, was found to be greater than that attached via simple chemisorption (in an open-circuit configuration). The quantity of metals released by the MT adsorbates, measured by electrochemical inductively coupled plasma-atomic emission spectrometry (EC/ICP-AES), was found to constitute 3.8% of the total mass measured by FI-EQCM. The average number of cysteines per MT molecule involved in the Hg-cysteine thiolate formation was found to be 4.2 1.8. Thus, it appears that about 1–2 metal ions (Cd) per MT molecule have been released off the TMF electrode since the stoichiometric ratio between the Cd and the cysteines in a MT molecule is known to be 1/3. The quantitative measurements by the two hybrid electrochemical methods (FI-EQCM and EC/ICP-AES) help elucidate the electrode reactions of MT adsorbates at TMF surfaces and the MT metal transfer processes. © 2001 Published by Elsevier Science B.V.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Interactions between Metallothionein and Cisplatin by using Differential Pulse Voltammetry Brdickás reaction and Quartz Crystal Microbalance

Treatment strategies for tumour diseases are progressively focusing on personalization of medicine. However, this focus requires methods revealing the early general biological mechanisms, including the formation anti-cancer drugs' resistance. The low molecular mass protein metallothionein is thought to be the crucial for the formation of resistance in tumour treatment based on the platinum-cyto...

متن کامل

Hierarchical Thin Film Architectures for Enhanced Sensor Performance: Liquid Crystal-Mediated Electrochemical Synthesis of Nanostructured Imprinted Polymer Films for the Selective Recognition of Bupivacaine

Nanostructured bupivacaine-selective molecularly imprinted 3-aminophenylboronic acid-p-phenylenediamine co-polymer (MIP) films have been prepared on gold-coated quartz (Au/quartz) resonators by electrochemical synthesis under cyclic voltammetric conditions in a liquid crystalline (LC) medium (triton X-100/water). Films prepared in water and in the absence of template were used for control studi...

متن کامل

Dominant Role of Molybdenum in the Electrochemical Deposition of Biological Macromolecules on Metallic Surfaces

The corrosion of CoCrMo, an alloy frequently used in orthopedic implants, was studied with an electrochemical quartz crystal microbalance (QCM) in three physiologically relevant solutions. Mass changes were measured during potentiodynamic tests, showing material deposition in protein solutions at potential levels that caused mass loss when the proteins were not present. X-ray photoelectron spec...

متن کامل

Electrochemistry of tert-Butylcalix[8]arene-C(60) Films Using a Scanning Electrochemical Microscope-Quartz Crystal Microbalance.

The electrochemical reduction of tert-butylcalix[8]arene-C(60) particle films was studied using the scanning electrochemical microscope combined with a quartz crystal microbalance (QCM) for several electrolytes in MeCN. Complexation of the fullerene within the film results in a negative shift of the peak potential of the first cathodic wave by about 400 mV compared to the reduction of a pure C(...

متن کامل

Scanning electrochemical microscopy. 36. A combined scanning electrochemical microscope-quartz crystal microbalance instrument for studying thin films.

The design of a combined scanning electrochemical microscope-quartz crystal microbalance (SECM-QCM) with separate potential control of the tip and substrate is described. Both lateral and vertical tip movements near the substrate affect the QCM resonant frequency because of perturbations of the longitudinal and shear waves of the quartz crystal (QC) acoustic wave sensor. The SECM-QCM was used t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001