Quantitative analysis of normal fetal brain volume and flow by three-dimensional power Doppler ultrasound.

نویسندگان

  • Ju-Chun Hsu
  • Yi-Cheng Wu
  • Peng-Hui Wang
  • Hsing-I Wang
  • Chi-Mou Juang
  • Yi-Jen Chen
  • Chia-Ming Chang
  • Huann-Cheng Horng
  • Chih-Yao Chen
  • Ming-Jie Yang
  • Ming-Shyen Yen
  • Kuan-Chong Chao
چکیده

BACKGROUND Assessment of the fetal brain volume and blood flow is important in the evaluation of fetal growth. We used three-dimensional (3D) ultrasound and power Doppler to assess the fetal brain volume and the blood flow index during normal gestation. The relationships of these parameters were further analyzed. METHODS We assessed the total volume and the blood flow index of the fetal brain in normal pregnancies using 3D ultrasound (Voluson 730). The bilateral parietal diameter (BPD) plane was measured by a 3D transabdominal probe to scan the fetal brain under the power Doppler mode. Then, we quantitatively assessed the total volume of the fetal brain, mean grey area (MG), vascularization index (VI), flow index (FI), and vascularization-flow index (VFI) by applying Kretz VOCAL software. RESULTS The study included 126 fetuses, ranging from 15 to 38 weeks of gestation. The total volume of the fetal brain was highly positively correlated with the gestational age (GA) (correlation coefficient [r] = 0.976, p < 0.0001). The MG, VI, and VFI were negatively correlated with the GA (correlation coefficient [r] = -0.520, p < 0.0001; [r] = -0.421, p < 0.001; [r] = -0.319, p < 0.0001). The FI was positively correlated with the GA (correlation coefficient [r] = 0.483, p < 0.0001). CONCLUSION 3D ultrasound can be used to assess the fetal brain volume and blood flow development quantitatively. Our study indicates that the fetal brain vascularization and blood flow correlates significantly with the advancement of GA. This information may serve as a reference point for further studies of the fetal brain volume and blood flow in abnormal conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional Power Doppler Ultrasound Study of the Placenta

Advanced ultrasound technology has been a valuable tool in the assessment of placental anatomy and physiology. Con­ ventional two­dimensional (2D) sonography reveals placental morphological characteristics, 2D color Doppler can assess blood flow in the placenta, 2D power Doppler can evaluate placental vascular trees, and three­dimensional (3D) ultra­ sound gives more detailed information on the...

متن کامل

Clinical application of three-dimensional ultrasound in fetal brain assessment.

AIM To clarify the usefulness of three-dimensional (3D) ultrasound in the assessment of the fetal head and brain, according to 3D ultrasound surface reconstruction, multiplanar image analysis, three-dimensional angiography, and volume calculation. METHODS We examined 326 normal fetuses between 10 and 40 weeks of gestation using 3D ultrasound (Voluson, 530D, Medison, Seoul, Korea), mainly with...

متن کامل

O-28: Anti-Mullerian Hormone and 3D-Power Doppler Histogram: Markers of Ovarian Function with In vitro Fertilization Treatment

Background: The aim of this study was to investigate the ability of three-dimensional (3D) ultrasonography and anti-Mullerian hormone (AMH) to predict successful embryo development in patients undergoing in vitro fertilization (IVF) treatment. Materials and Methods: We prospectively studied 28 patients undergoing IVF treatment, using 3D ultrasound Sono automatic volume calculation (AVC) and a 3...

متن کامل

Three-dimensional Power Doppler Ultrasonographic Evaluation of Induced Cystitis in Dogs

Objectives: The aim of this study was to investigate if three-dimensional power Doppler (3DPD) ultrasound (US) can detect bacterial cystitis in dogs better than two-dimensional (2D) US. Animals: Six mixed breed dogs Procedures: Ten ml of 0.1% alcoholic solution of salicylic acid was entered into the urinary bladder of six male mixed-breed dogs by catheter. Twenty four hours later, culture sol...

متن کامل

Biological Effect of Modern Fetal Ultrasound Techniques on Human Dermal Fibroblast Cells

Background: Diagnostic ultrasound has been used to detect human disease especially fetus abnormalities in recent decades. Although the harmful effects of diagnostic ultrasound on human have not been established so far, several researchers showed it has had bioeffects in cell lines and in experimental animals. Three-dimensional (3D), four-dimensional (4D), and color Doppler sonography are new te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Chinese Medical Association : JCMA

دوره 76 9  شماره 

صفحات  -

تاریخ انتشار 2013