Detecting errors in blood-gas measurement by analysis with two instruments.

نویسندگان

  • L F Metzger
  • W B Stauffer
  • A V Krupinski
  • R P Millman
  • G S Cembrowski
  • A I Pack
چکیده

We performed a two-stage prospective evaluation of the error detection capabilities of duplicate analysis of blood-gas specimens. In the first stage we analyzed 1601 specimens with a Corning Model 175 blood-gas analyzer as the test instrument and a Corning Model 178 analyzer as the reference instrument, and in the second stage we analyzed 1544 specimens with two Model 178 analyzers. In each stage the designated reference instrument underwent troubleshooting whenever an analytical error was detected; the test instrument underwent troubleshooting only when error conditions were indicated by means other than duplicate analysis. An error was considered to have occurred if the difference between the duplicate analyses exceeded 0.02 (for pH), 0.53 kPa, i.e., 4 mmHg (pCO2), or 7% (pO2). The number of specimens for which errors were detected was 97 (6.1%) in the first stage, 23 (1.5%) in the second. For each analyte more errors were detected with the Model 175 analyzer (of older design) than with the newer Model 178 analyzer. Furthermore, in certain periods associated with the use of particular electrodes there were very high error rates for individual analytes: 8% for pCO2, 18% for pO2. We conclude that duplicate analysis should be considered as a possible required standard for error detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Instrumental Variables Regression with Measurement Errors and Multicollinearity in Instruments

In this paper we obtain a consistent estimator when there exist some measurement errors and multicollinearity in the instrumental variables in a two stage least square estimation of parameters. We investigate the asymptotic distribution of the proposed estimator and discuss its properties using some theoretical proofs and a simulation study. A real numerical application is also provided for mor...

متن کامل

Use of equilibrated blood for internal blood-gas quality control.

We have used equilibrated human blood for blood-gas quality control since 1970. In blood equilibrated 24 h after shedding, gas tensions are stable for 4 to 6 h at 0 to 4 degrees C; each control specimen is analyzed several times during that period to resolve malfunctions, etc. Three-fourths of all errors in gas-tension measurement detected with equilibrated blood were detected with the highest-...

متن کامل

Comparison of Two Human Error Evaluation Techniques (HET and SHERPA) in Gas Supply Operations using AHP

Introduction: The development of residential and industrial areas has led to increasing gas consumption and overcrowding in gas supply networks. Accordingly, hazards and risks caused by human errors, processing and mechanical failures in pipelines, and gas leaks are on a rise. Several techniques have been so far proposed for identifying and controlling human errors. The main purpose of this stu...

متن کامل

The Effect of Gauge Measurement Capability and Dependency Measure of Process Variables on the MCp

It has been proved that process capability indices provide very efficient measures of the capability of processes from many different perspectives. These indices have been widely used in the manufacturing industry for measuring process reproduction capability according to manufacturing specifications. In the past few years, univariate capability indices have been introduced and used to characte...

متن کامل

Human Error Assessment in City Gate Stations of Isfahan Natural Gas Company Using the System for Predictive Error Analysis and Reduction Framework

Introduction: Human factor analysis has been identified as the most common cause of accidents in natural gas transportation and distribution facilities. The occurrence of accidents at these systems, especially gas reduction stations located in residential and industrial areas, has had catastrophic consequences. Therefore, this study aimed at analyzing critical tasks and human error assessment u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 33 4  شماره 

صفحات  -

تاریخ انتشار 1987