An estimate of the size and shape of the human lens fibre in vivo.

نویسندگان

  • N A Brown
  • A J Bron
  • J M Sparrow
چکیده

The size and shape of the lens fibres were estimated by specular reflex photography. The fibres were measured in three separate regions. Peripheral fibres have a mean width of 10.2 micron, the central fibres 11.9 micron, and the central fibres with suture 15.8 micron. Measurements were made of the taper (becoming narrower towards the suture) and flare (becoming wider towards the suture). The peripheral fibres have a mean taper of 0.3 micron per 100 micron. The central fibres have a mean flare of 0.6 micron per 100 micron, and the central fibres with suture have a mean flare of 2.4 micron per 100 micron. These differences are highly significant (p less than 10(-6]. From these measurements the overall shape of the average lens fibre was estimated. This fibre tapers as it passes forward from the equator to the peripheral extent of the lens sutures and then flares increasingly as the junction with the lens suture is approached. A mean increase in peripheral lens fibre width with age at 0.028 micron per year was demonstrated. This is significant (p = 0.042). No difference in fibre width was found in diabetics and non-diabetics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients

Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...

متن کامل

Comparison of Absorbed Dose in Thyroid and Lens as Organs at Risk Between in vivo Dosimetry and 3-D Treatment Planning Calculation in Head and Neck Radiotherapy by Linac Beam

Introduction: Critical organs and structures may receive significant amounts of irradiation even if they are not the target of radiotherapy or located outside the treatment field. Although the sensitive thyroid gland and lens are not directly the targets of treatment, they can be affected by irradiation during the treatment of tumours in head and neck region. The purpose of thi...

متن کامل

The Influence of Meiotic Spindle Configuration by Cysteamine during in vitro Maturation of Mouse Oocytes

Background: The aim of this study was to assess effects of cysteamine as an anti-oxidant on rate of in vitro maturation of oocyte and determination of its effects on spindle size and shape. Methods: Pre-mature mice were primed with pregnant mare stimulating gonadotrophin (PMSG) and germinal vesicle (GV) stage oocytes were obtained 48 h after. The oocytes were cultured in tissue culture medium (...

متن کامل

To Estimate the Axial Elastic Modulus of Eye and Posterior Wall Thickness in Healthy Human Eye by Ultrasound Images and their Relation with Age and Gender

Introduction: Based on the invasive studies it has been shown that factors such as age, the progress of eye disorders, lens fibers compression and the biochemical changes of ocular matrix alter the physical characteristics and elastic properties of eye. In this study, a noninvasive method of estimating human eye elasticityis proposed and its relation with age and gender is evaluated using ultra...

متن کامل

تخمین غیرتهاجمی مدول الاستیک چشم کاتاراکته شده خرگوش

    Although cataract is very common and its detection seems apparently easy especially in the mature cataract, its quantitative description to determine the critical value of diagnosis is too difficult. Non-invasive evaluation of the mechanical properties of eye is hampered by the absence of in-vivo methods for direct assessment of the axial length of eye, lens and cornea. In the present study...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 71 12  شماره 

صفحات  -

تاریخ انتشار 1987