Design and finite element-based fatigue prediction of a new self-expandable percutaneous mitral valve stent

نویسندگان

  • Gideon Praveen Kumar
  • Fangsen Cui
  • Asawinee Danpinid
  • Boyang Su
  • Jimmy Kim Fatt Hon
  • Hwa Liang Leo
چکیده

Percutaneous heart valve replacement is currently limited to the replacement of pulmonary and aortic valves in a targeted group of patients. Designing a heart valve for mitral valve replacement is further limited by its distinctive anatomical feature, which places a constraint on its range of design options. To overcome such limitations, the objectives of this study were to use computational modeling and simulation to design a new Nitinol-based mitral valve stent and evaluate its crimpability and fatigue behavior. A self-expandable stent with new features that could address issues of valve migration and paravalvular leaks was generated using CAD based conceptual modeling. Its expansion, crimpability, deployment patterns, and fatigue behavior were simulated and analyzed. Our simulations incorporated cyclic cardiac muscle loading, cyclic blood pressure loading, as well as cyclic valve-leaflet forces in the fatigue life assessment for mitral valves. Our results showed that the stent model passed the fatigue test under the aforementioned loading conditions. Our model provides a simple, fast and cost-effective tool to quantitatively determine the fatigue resistance of stent components. This is of great value to the design of new prosthetic heart valve models, as well as to surgeons involved in valve replacement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent

Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...

متن کامل

Percutaneous treatment of valvular heart disease: catheter-based aortic valve replacement and mitral valve repair therapies.

Until recently, percutaneous catheter therapy for valvular heart disease was limited to catheter balloon valvuloplasty for aortic, mitral, or pulmonic stenosis. A number of new approaches to percutaneous valve therapy are now developing rapidly, including methods for catheter-based valve replacement and repair. Stent-mounted valve prostheses have been successfully implanted in the pulmonic and ...

متن کامل

Application of finite element analysis to the design of tissue leaflets for a percutaneous aortic valve.

Percutaneous Aortic Valve (PAV) replacement is an attractive alternative to open heart surgery, especially for patients considered to be poor surgical candidates. Despite this, PAV replacement still has its limitations and associated risks. Bioprosthetic heart valves still have poor long-term durability due to calcification and mechanical failure. In addition, the implantation procedure often p...

متن کامل

Off-pump transapical mitral valve-in-ring implantation.

OBJECTIVES The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass usin...

متن کامل

SHORT TERM CLINICAL OUTCOME OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY VERSUS SURGICAL CLOSED MITRAL COMMISSUROTOMY

BaIlon mitral valvuloplasty and closed mitral valve conunissurotomy were performed in 450 and 127 patients, respectively. Also, 254 patients with severe mitral stenosis were enrolled in a prospective randomized trial comparing the two procedures. Immediately after balloon mitral valvuloplasty, mean left atrial pressure was 11.38±3.54 mmHg, transmitral valve gradient was 1.8±2 mmHg, and mit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer-Aided Design

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2013