Palmar and dorsal fixed-angle plates in AO C-type fractures of the distal radius: is there an advantage of palmar plates in the long term?

نویسندگان

  • Michael G Jakubietz
  • Joerg G Gruenert
  • Rafael G Jakubietz
چکیده

BACKGROUND Current surgical approaches to the distal radius include dorsal and palmar plate fixation. While palmar plates have gained widespread popularity, few reports have provided data on long term clinical outcomes in comparison. This paper reports the result of a randomised clinical study comparing dorsal Pi plates and palmar, angle-stable plates for treatment of comminuted, intraarticular fractures of the distal radius over the course of twelve months. METHODS 42 patients with unilateral, intraarticular fractures of the distal radius were included and randomised to 2 groups, 22 were treated with a palmar plate, 20 received a dorsal Pi-plate. Results were evaluated after 6 weeks, 3, 6 and 12 months postoperatively focussing on functional recovery as well as radiological results. RESULTS The palmar plate group demonstrated significantly better results regarding range of motion and grip strength over the course of 12 months. While a comparable increase in function was observed in both groups, the better results from the early postoperative period in the palmar plate group prevailed over the whole course. Radiological results showed a significantly increased palmar tilt and carpal sag in dorsal plates, with other radiological parameters being comparable. Pain levels were decreased in dorsal plates after hardware removal and failed to show significant differences after 12 months. However, complications such as tendon ruptures were more frequent in the dorsal plate group. CONCLUSIONS Functional advantage of palmar plates gained within the first 6 weeks prevails over the course of a year. Both groups demonstrate further gradual increase of function after 6 months, although dorsal plates did not catch up completely. Improved early postoperative function seems to be the cornerstone for the best possible results. Patients with dorsal plates benefit from hardware removal more than palmar plates in terms of reduction of pain levels. The advantage of palmar plates is a faster functional recovery with lower complication rates. This is especially important in the elderly population. Radiological results did not show a superiority of palmar plates over dorsal plates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal radius measurements and efficacy of fixed-angle locking volar plates.

AIM For surgical treatment of unstable distal radius fractures, fixed-angled locking volar plate fixation is becoming popular nowadays because of some advantages over other surgical techniques. In this article, we discuss the fitting of fixed-angle locking volar plates to the distal radius in relation to the changes in the distal radial angles. MATERIALS AND METHODS First, we took conventiona...

متن کامل

Locking versus nonlocking palmar plate fixation of distal radius fractures.

This study compared functional and radiological outcomes after treatment of extension-type distal radius fractures with conventional titanium nonlocking T-plates or titanium 1.5-mm locking plates. A total of 60 patients were included and followed for 4 to 7 years after receiving nonlocking T-plates (group A; n=30) or locking plates (group B; n=30) with and without dorsal bone grafting. Bone gra...

متن کامل

Fracture heuristics: surgical decision for approaches to distal radius fractures. A surgeon’s perspective

Introduction: The aim of the present study is to develop a heuristic that could replace the surgeon's analysis for the decision on the operative approach of distal radius fractures based on simple fracture characteristics. Patients and methods: Five hundred distal radius fractures operated between 2011 and 2014 were analyzed for the surgeon's decision on the approach used. The 500 distal radius...

متن کامل

Short-term Results of Using Injectable Bone Cement Technique in the Treatment of Unstable Distal Radius Fractures

Background & Aims: Treatment of osteoporotic distal radius fracture with metaphyseal defect is often complicated by secondary displacement, because of posterior cortex comminution. The aim of this study was to investigate functional outcomes and advantages of injection of bone cement in stabilizing and maintaining this fracture reduction. Methods: This prospective study was performed on 20 ...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012