Radiography by computed tomography for dental and jaw use (dental CT) has recentry attracted attention as a new diagnostic imaging technique in dentistry. The 3DX Multi-Image Micro CT® (3DX, Morita) is the first exclusively registered dental CT in Japan. A high-definition 3-dimensional image of a cylindrical imaging area, 40 mm in diameter and 30 mm in height, can be taken by using a small-type conical beam X-ray CT. An arbitrary part can be sliced and observed from 3 different directions by using a 3DX-exclusive integrated image processing software, and it can be re-sliced repeatedly at arbitrary angles to reconstruct other images. Pictures of 3DX can be taken by a low dose of irradiation equal to that used for panoramic radiography. Therefore, this device is very effective for the examination and diagnosis of hard tissues of the maxillofacial region. This study evaluated the effectiveness of the 3DX for examining and diagnosing various clinical cases in endodontic therapy. The image obtained by 3DX clearly revealed the presence and expansion of periapical lesions of roots, the presence and position of root fracture, and perforations, as well as afforded prognosis. In conclusion, the 3DX, a newly developed dental CT, is very useful to examine cases of the above-mentioned disorders that can not be easily identified by the usual intraoral radiography or panoramic radiography, and it thus allows proper diagnosis of such cases. Key word: Dental Computed Tomography, Diagnostic Imaging, Perforation Introduction In endodontic therapy, the quality and quantity of the information obtained from radiographic examinations is very important because it affects the diagnosis, treatment planning, and prognostic stability. Sometimes in daily clinical practice, there are some cases where the conventional intraoral radiography or panoramic radiography alone does not provide enough information for diagnosis. Computed tomography (CT) can provide detailed 3-dimensional observation and thus is useful in the diagnosis of endodontic problems requiring therapy. However, the radiation dose of a single CT session is much higher than that used for intraoral radiography or panoramic radiography. Recently, the 3DX Multi-Image Micro CT® (3DX) (J. Morita Mfg. Co., Kyoto, Japan), a new X ray photography apparatus that can provide very suitable images and was first produced in Japan, has attracted much attention. A high-resolution 3-dimensional image of a cylindrical imaging area, 40 mm in diameter and 30 mm in height, can be taken. An image can be sliced in an optional part. By using 3DX-exclusive integrated image-processing software (i-VIEW®), the device can produce an image from 3 different directions and re-slice the image repeatedly at arbitrary angles. Since the 3DX was just recently introduced, there are few reports about its usefulness in endodontic therapy. In the present study, therefore, we evaluated the effectiveness of the 3DX for examining and diagnosing various clinical cases in endodontic therapy. Case Report The image obtained by 3DX clearly revealed the presence and expansion of periapical lesions of roots (Fig. 1), the presence and position of root fractures (Fig. 2), perforation (Fig. 3), and instrument separation (Fig. 4), as well as afforded prognosis (Fig. 5). Discussion The 3DX is especially excellent in generating an informative image database at a low irradiation dose, which is equivalent to that of about 2 exposures by intraoral radiography, that of about the same by panoramic radiography, and that of about 1/100 -1/ 30 by the medical X-ray CT in as little as 17 seconds of exposure time. Also, this dental CT has about 8 times higher resolution than the medical CT. Therefore, this device is thought to be useful for the examination and diagnosis of hard tissues of the maxillofacial region, including teeth, alveolar bone, and the jaws. Correspondence to Kazuyoshi Suzuki, Department of Endodontics, School of Dentistry, Aichi-Gakuin University, 2-11 Suemori-dori, Chikusa-ku, Nagoya, 464-8651, JAPAN,TEL: +81-52-759-2148 FAX: +81-52-7642299,e-mail: [email protected] Fig.1 3DX-CT image of a periapical lesion
منابع مشابه
Validation of Carotid Duplex and Power M-mode Transcranial Doppler for Detection of Internal Carotid Artery Stenosis
Background – Carotid duplex ultrasound (CDU) is routinely used for detection of extracranial internal carotid artery (EICA) stenosis in stroke patients. Power M-mode transcranial Doppler (PMD-TCD) is a new technology designed for studying intracranial vessels. This prospective study was performed for validation of CDU versus digital subtraction cerebral angiography (DSA) and PMD-TCD versus CDU ...
متن کاملApplications and advantages of power motion-mode Doppler in acute posterior circulation cerebral ischemia.
BACKGROUND AND PURPOSE Evaluation of posterior circulation with single-gate transcranial Doppler (TCD) is technically challenging and yields lower accuracy parameters in comparison to anterior circulation vessels. Transcranial power motion-mode Doppler (PMD-TCD), in addition to spectral information, simultaneously displays in real-time flow signal intensity and direction over 6 cm of intracrani...
متن کاملDistinct neural patterns enable grasp types decoding in monkey dorsal premotor cortex.
OBJECTIVE Recent studies have shown that dorsal premotor cortex (PMd), a cortical area in the dorsomedial grasp pathway, is involved in grasp movements. However, the neural ensemble firing property of PMd during grasp movements and the extent to which it can be used for grasp decoding are still unclear. APPROACH To address these issues, we used multielectrode arrays to record both spike and l...
متن کاملAccuracy of transcranial Doppler compared with CT angiography in diagnosing arterial obstructions in acute ischemic strokes.
BACKGROUND AND PURPOSE Patients with acute ischemic stroke and intracranial arterial obstructions have a poor prognosis and a high probability of deteriorating at 24 hours. We aimed to evaluate the diagnostic accuracy of power motion mode Doppler (PMD-TCD) compared with CT angiography as standard in diagnosing intracranial arterial obstructions in patients presenting with ischemic stroke of <24...
متن کاملStorage of Seeds
Introduction 86 Factors Affecting Longevity of Seeds 86 Seed Characteristics 86 Basic seed physiology 86 Seed morphology 88 Chemical composition 88 Seed maturity 89 Seed Handling Prior to Storage 89 Storage Environment 89 Moisture 89 Temperature 90 Atmosphere 91 Storage Facilities 92 Cold storage 92 Containers 92 Moisture Control 93 Storage Recommendation 93 Orthodox Seeds 93 Temperate-Recalcit...
متن کاملکنترل همزمان شتاب و تغییرمکان لرزه ای سازه های نامتقارن چند طبقه با استفاده از میراگرهای جرمی غیر فعال (PMD)
مطالعات اخیر نشان داده که میراگر جرمی غیرفعال می تواند پاسخ تغییرمکان حداکثر سازه های نامتقارن رابه طور مناسبی کاهش دهد. ولی در اکثر سازه ها کاهش همزمان شتاب و تغییرمکان دو لبه از اهمیت بالاییبرخوردار است. در این مقاله کنترل لرزه ای ساختمانهای نامتقارن یک، چهار و هشت طبقه با خصوصیاتمختلف پیچشی با استفاده از میراگر جرمی با مشخصات و موقعیتهای مختلف مورد مطاله قرار گرفت. کاهشحداکثر تغییرمکان و شتا...
متن کامل