Echocardiographic evaluation of a TASER-X26 application in the ideal human cardiac axis.

نویسندگان

  • Jeffrey D Ho
  • Donald M Dawes
  • Robert F Reardon
  • Anne L Lapine
  • Benjamin J Dolan
  • Erik J Lundin
  • James R Miner
چکیده

OBJECTIVES TASER electronic control devices (ECDs) are used by law enforcement to subdue aggressive persons. Some deaths temporally proximate to their use have occurred. There is speculation that these devices can cause dangerous cardiac rhythms. Swine research supports this hypothesis and has reported significant tachyarrhythmias. It is not known if this occurs in humans. The objective of this study was to determine the occurrence of tachyarrhythmias in human subjects subjected to an ECD application. METHODS This was a prospective, nonblinded study. Human volunteers underwent limited echocardiography before, during, and after a 10-second TASER X26 ECD application with preplaced thoracic electrodes positioned in the upper right sternal border and the cardiac apex. Images were analyzed using M-mode through the anterior leaflet of the mitral valve for evidence of arrhythmia. Heart rate (HR) and the presence of sinus rhythm were determined. Data were analyzed using descriptive statistics. RESULTS A total of 34 subjects were enrolled. There were no adverse events reported. The mean HR prior to starting the event was 108.7 beats/min (range 65 to 146 beats/min, 95% CI = 101.0 to 116.4 beats/min). During the ECD exposure, the mean HR was 120.1 beats/min (range 70 to 158 beats/min, 95% CI = 112.2 to 128.0 beats/min) and a mean of 94.1 beats/min (range 55 to 121 beats/min, 95% CI = 88.4 to 99.7 beats/min) at 1 minute after ECD exposure. Sinus rhythm was clearly demonstrated in 21 (61.7%) subjects during ECD exposure (mean HR 121.4 beats/min; range 75 to 158 beats/min, 95% CI = 111.5 to 131.4). Sinus rhythm was not clearly demonstrated in 12 subjects due to movement artifact (mean HR 117.8 beats/min, range 70 to 152 beats/min, 95% CI = 102.8 to 132.8 beats/min). CONCLUSIONS A 10-second ECD exposure in an ideal cardiac axis application did not demonstrate concerning tachyarrhythmias using human models. The swine model may have limitations when evaluating ECD technology.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echocardiographic evaluation of TASER X26 probe deployment into the chests of human volunteers.

Several animal studies have shown that the TASER X26 (TASER International, Scottsdale, Ariz) conducted electrical weapon can electrically capture the myocardium when discharged on the thorax. These results have not been reproduced in human echocardiographic studies. A primary limitation of those human studies is that the TASER device was connected by taping the wires into conductive gel on the ...

متن کامل

Risk of Pacemaker Patients by TASER X26 Contact Mode Application

The prevalence of pacemaker patients among the general population and of conducted energy devices (CED) for law enforcement and self-defence is increasing. Consequently, the question whether cardiac pacemaker (CPM) patients are on particular risk becomes increasingly important. The risk of Taser X26 electric interference with implanted CPM has been investigated by numerical simulation at MRI-ba...

متن کامل

Defence Scientific Advisory Council Sub-Committee on the Medical Implications of Less-Lethal Weapons (DOMILL) Statement on the Medical Implications of Use of the Taser X26 and M26 Less-Lethal Systems on Children and Vulnerable Adults

2. DOMILL has issued five previous statements relating to the medical implications of the Taser M26 and Taser X26 less-lethal systems. 4 The Taser X26 conducted energy device was introduced into UK policing in 2005 as a replacement for the Taser M26. Recent data from the Home Office Centre for Applied Science and Technology (CAST) indicate that the Taser X26 is the device primarily in use by th...

متن کامل

The neuroendocrine effects of the TASER X26: a brief report.

INTRODUCTION Law enforcement officers use conducted electrical weapons (CEW) such as the TASER X26 to control violently resistive subjects. There are no studies in the medical literature examining the effects of these weapons on the human stress response. This is the first study to compare the human stress response to conducted electrical weapons, oleoresin capsicum (O.C.), a cold-water tank im...

متن کامل

TASER X26 discharges in swine produce potentially fatal ventricular arrhythmias.

OBJECTIVES Data from the authors and others suggest that TASER X26 stun devices can acutely alter cardiac function in swine. The authors hypothesized that TASER discharges degrade cardiac performance through a mechanism not involving concurrent acidosis. METHODS Using an Institutional Animal Care and Use Committee (IACUC)-approved protocol, Yorkshire pigs (25-71 kg) were anesthetized, paralyz...