Optimization of Medical Accelerators*
نویسنده
چکیده
The Optimization of Medical Accelerators (OMA) is the aim of a new European training network. OMA joins universities, research centers and clinical facilities with industry partners to address the challenges in treatment facility design and optimization, numerical simulations for advanced treatment schemes, and beam imaging and treatment monitoring. Projects include: compact accelerators for proton beam energy boosting and gantry design; strategies for improving Monte Carlo codes for medical applications and treatment planning; and advanced diagnostics for online beam monitoring. The latter involves RF-based measurements of ultra-low charges and new encoding methodologies for ultra-fast 3D surface scanning. This paper presents an overview of the network's research program and highlights the various challenges across the 3 scientific work packages. It also summarizes the network-wide training program consisting of schools, topical workshops and conferences that will be open to the wider medical and accelerator communities.
منابع مشابه
Beam Diagnostics for Medical Accelerators*
The Optimization of Medical Accelerators (OMA) is the aim of a new European Training Network that has received 4 ME of funding within the Horizon 2020 Programme of the European Union. OMA joins universities, research centers and clinical facilities with industry partners to address the challenges in treatment facility design and optimization, numerical simulations for the development of advance...
متن کاملNew Method of Quality Control Test for Light and Radiation Field Coincidence in Medical Linear Accelerators
Introduction: The evaluation of X-ray and light field coincidence in linear accelerators as a quality control test is often performed subjectively, involving the manual marking of films and their visual inspection following the irradiation. Therefore, the present study aimed to develop an objective method for the performance of this test leading to the increased levels...
متن کاملUnexpected dose and the biological effect of neutron contamination in linear accelerators
Employing High-energy photons in medical linear accelerators can lead to neutron contamination. The relative biological effect of neutrons is 20 times higher than photons. Consequently, its damage to the biological tissue is much higher and unobtrusive. In this study, we calculated neutron equivalent dose in a medical linear accelerator by the FLUKA Monte Carlo code system. The results show tha...
متن کاملبررسی وضعیت شتابدهنده خطی الکترون در درمان سرطان در ایران
Medical electronlinear accelerators are the most practical radiotherapy facilities in cancer treatment. About 52 percent of patients are treated by these radiotherapy systems during their treatment process. However, in developing countries there are not enough systems and recent studies reported the shortage of 5000 megavoltage radiotherapy accelerators all over the world. According to internat...
متن کاملAssessment of skyshine photon dose rates from 9 and 18 MV medical linear accelerators
Background: Skyshine describes the radiation scattered by the atmosphere above a LINAC facility to a point on the ground. The aim of this study was to measure the skyshine photon dose rates from two different (9 MV and 18 MV) medical linear accelerators. Materials and Methods: The photon beam was directed upward (180° gantry position), with a maximum photon field size (40 × 40 cm2) at the isoce...
متن کامل