Radioactive stents delay but do not prevent in-stent neointimal hyperplasia.

نویسندگان

  • I P Kay
  • A J Wardeh
  • K Kozuma
  • D P Foley
  • A H Knook
  • A Thury
  • G Sianos
  • W J van der Giessen
  • P C Levendag
  • P W Serruys
چکیده

BACKGROUND Restenosis after conventional stenting is almost exclusively caused by neointimal hyperplasia. Beta-particle-emitting radioactive stents decrease in-stent neointimal hyperplasia at 6-month follow-up. The purpose of this study was to evaluate the 1-year outcome of (32)P radioactive stents with an initial activity of 6 to 12 microCi using serial quantitative coronary angiography and volumetric ECG-gated 3D intravascular ultrasound (IVUS). METHODS AND RESULTS Of 40 patients undergoing initial stent implantation, 26 were event-free after the 6-month follow-up period and 22 underwent repeat catheterization and IVUS at 1 year; they comprised half of the study population. Significant luminal deterioration was observed within the stents between 6 months and 1 year, as evidenced by a decrease in the angiographic minimum lumen diameter (-0.43+/-0.56 mm; P:=0.028) and in the mean lumen diameter in the stent (-0.55+/-0. 63 mm; P:=0.001); a significant increase in in-stent neointimal hyperplasia by IVUS (18.16+/-12.59 mm(3) at 6 months to 27.75+/-11. 99 mm(3) at 1 year; P:=0.001) was also observed. Target vessel revascularization was performed in 5 patients (23%). No patient experienced late occlusion, myocardial infarction, or death. By 1 year, 21 of the initial 40 patients (65%) remained event-free. CONCLUSIONS Neointimal proliferation is delayed rather than prevented by radioactive stent implantation. Clinical outcome 1 year after the implantation of stents with an initial activity of 6 to 12 microCi is not favorable when compared with conventional stenting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Edge Restenosis After Implantation of High Activity P Radioactive b-Emitting Stents

Background—A high restenosis rate has been reported at the edges (“edge restenosis”) of P radioactive stents with an initial activity level of 3 to 12 mCi. This edge effect might be due to balloon injury and to a low dose of radiation at the stent margins. The aim of this study was to evaluate whether the implantation of P radioactive stents with a higher activity level (12 to 21 mCi) combined ...

متن کامل

Oversizing of self-expanding stents: influence on the development of neointimal hyperplasia of the carotid artery in a canine model.

BACKGROUND AND PURPOSE In carotid artery stent placement, marked oversizing of the stent relative to the internal carotid artery lumen is common. This study was performed to determine the influence of using oversized self-expanding nitinol stents on neointimal hyperplasia. METHODS In six greyhound dogs, 24 self-expanding nitinol stents (eight SMART stents, eight Easy Wallstents, eight Sinus-F...

متن کامل

"Edge Effect" of (32)p radioactive stents is caused by the combination of chronic stent injury and radioactive dose falloff.

BACKGROUND Radioactive stents have been reported to reduce in-stent neointimal thickening. An unexpected increase in neointimal response was observed, however, at the stent-to-artery transitions, the so-called "edge effect." To investigate the factors involved in this edge effect, we studied stents with 1 radioactive half and 1 regular nonradioactive half, thereby creating a midstent radioactiv...

متن کامل

“Edge Effect” of P Radioactive Stents Is Caused by the Combination of Chronic Stent Injury and Radioactive Dose Falloff

Background—Radioactive stents have been reported to reduce in-stent neointimal thickening. An unexpected increase in neointimal response was observed, however, at the stent-to-artery transitions, the so-called “edge effect.” To investigate the factors involved in this edge effect, we studied stents with 1 radioactive half and 1 regular nonradioactive half, thereby creating a midstent radioactiv...

متن کامل

Failure of a Novel Balloon-Expandable -Emitting (Pd) Stent to Prevent Edge Effects

Background—Balloon-expandable -particle–emitting (P) stents inhibit within-stent neointimal hyperplasia but induce lumen narrowing beyond the stent margins, ie, the so-called “edge effects.” Methods and Results—We prospectively investigated the performance of novel stents impregnated with the -emitting isotope Pd, designed to reduce edge effects, in 24 rabbits. The stents had a length of 18 mm ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 103 1  شماره 

صفحات  -

تاریخ انتشار 2001