Straylight measurements in pseudophakic eyes with natural and dilated pupils: one-year follow-up.
نویسندگان
چکیده
PURPOSE To compare the amount of straylight in natural pupils and dilated pupils in pseudophakic eyes 6 weeks and 1 year after cataract extraction. SETTING Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. METHODS This study evaluated patients with bilateral age-related cataract who had cataract surgery with implantation of an aspheric Tecnis ZA9003 or spherical Sensar AR40e intraocular lens (IOL). Straylight measurements were performed with a C-Quant straylight meter 6 weeks after surgery (with natural pupils) and 1 year after surgery (with natural and dilated pupils) in a randomly chosen eye. Retroillumination photographs of dilated pupils were taken to document posterior capsule opacification. The main outcome variable for straylight measurements was the logarithmic straylight parameter, log(s). RESULTS Twenty-two patients were evaluated. There was a statistically significant decrease in straylight in a natural pupil between 6 weeks (mean 1.44 log[s]) and 1 year (mean 1.30 log[s]) postoperatively (P = .012). The straylight parameter was greater after dilation (mean 1.48 log[s]) than with a natural pupil (1.29 log[s]) at 1 year (P = .012). This difference was greater when more anterior capsule was visible in the pupillary area (P = .031). CONCLUSIONS Straylight decreased significantly in the first year after cataract surgery. Furthermore, it increased with increasing pupil size, which was associated with a capsulorhexis smaller than the pupil. This indicates the capsulorhexis should be as large as possible to prevent straylight, especially under low-luminance conditions when the pupil is large.
منابع مشابه
Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens
Purpose. To investigate the intraocular straylight value after cataract surgery. Methods. In this study, 76 eyes from 62 patients were subdivided into three groups. A hydrophobic acrylic, a hydrophilic acrylic, and a PMMA IOL were respectively, implanted in 24 eyes, 28 eyes, and 24 eyes. Straylight was measured using C-Quant at 1 week and 1 month postoperatively in natural and dilated pupils. R...
متن کاملQuality of vision in patients with fuchs endothelial dystrophy and after descemet stripping endothelial keratoplasty.
OBJECTIVE To evaluate the quality of vision (visual acuity and straylight) in patients with Fuchs dystrophy and the improvement in visual quality after Descemet stripping endothelial keratoplasty (DSEK). METHODS There was an observational case series (Amsterdam group) and a prospective interventional case series (Mayo group). Corrected distance visual acuity (CDVA), straylight, and corneal th...
متن کاملStraylight effects with aging and lens extraction.
PURPOSE To assess possible gains and losses in straylight values among the population to consider straylight as added benefit of lens extraction. DESIGN In this cross-sectional design, data from a multicenter study on visual function in automobile drivers were analyzed. METHODS On both eyes of 2,422 subjects, visual acuity (logarithm of the minimum angle of resolution [logMAR] in steps of 0...
متن کاملThe significance of changes in pupil size during straylight measurement and with varying environmental illuminance.
PURPOSE In this work, we investigated the pupillary conditions during straylight measurement, and the potential effect this might have on the measured straylight. METHODS Five young (26-29-years-old) and 15 older (50-68-years-old) individuals participated in this study. First, the pupil diameter of both eyes was measured at three room illuminances. Next, straylight was assessed at two room il...
متن کاملComparison of ocular straylight after implantation of multifocal intraocular lenses.
UNLABELLED A comprehensive review of the effect of multifocal intraocular lens (IOL) designs on postoperative ocular straylight was performed. Studies reporting straylight values obtained with the natural pupil using the C-Quant device after uneventful multifocal IOL implantation were included. The IOLs were categorized based on their material characteristics; that is, hydrophobicity and presen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 36 6 شماره
صفحات -
تاریخ انتشار 2010