Research of hemodynamic change and oxygen metabolism during anesthesia of off-pump coronary artery bypass grafting (OPCABG)
نویسندگان
چکیده
Objectives: The purpose of this study is to evaluate the anesthesia methods by observing hemodynamic changes, oxygen supply and demand balance in order to provide the reference for the Off-Pump Coronary Artery Bypass Grafting (OPCABG) anesthesia management level during OPCABG. Methods: Thirty patients scheduled for elective OPCABG were premedicated with intramuscular scopolamine 0.3 mg/kg and morphine 0.15 mg, 30 min before anesthesia. Artery blood pressure was monitored through radial artery catheter. Hemodynamic and oxygen metabolism index was recorded respectively at preoperative (T1), after the sternal incision (T2), LAD anastomosis (T3), CX/DIA anastomosis (T4), RCA anastomosis (T5) and the end of the operation (T6). Results: The preload parameters change significantly at T1 and T5. Compared to T1, CVP and RVEDV decrease significantly at T4 (P<0.05), PCWP increase significantly at T5 (P<0.05). The afterload parameters change at T3 and T5. SVR and SVRI decrease significantly at T3 (P<0.01). SVRI decreases significantly at T5 (P<0.05). The cardiac systolic function was mainly influenced at T3, T4 and T5. Compared to T1, RVEF, CCO and CCI increase significantly (P<0.05), SV and SVI decreased significantly (P<0.01), RVEF increase significantly at T3 (P<0.05). The pressure related parameters change at T4 and T5. CVP decreases significantly at T4 (P<0.05), while PCWP increase significantly at T5 (P<0.05). Oxygen supply and demand balance parameters change at T2, T3, T4 and T5. O2ER and O2EI decrease significantly (P<0.01), Ca-vO2 decrease significantly at T2 (P<0.05). SvO2 increase significantly at T3 (P<0.01), increase relative slightly at T2 and decrease significantly compared to T1. DO2 and DO2I increase significantly (P<0.05), PvO2 increase significantly until T5 (P<0.01), but the lactic acid level decrease significantly (P<0.05). Conclusion: During the management of OPCABG anesthesia, maintaining the stable hemodynamic may ensure oxygen supply, demand balance and make the operation safe.
منابع مشابه
Anesthetic management of off-pump simultaneous coronary artery bypass grafting and lobectomy
RATIONALE Survey data show approximately 10% patients with lung cancer may present concomitant coronary heart disease. Simultaneous surgery is a challenge for anesthetist. We review our experience in the anesthesia with 5 patients who required simultaneous off-pump coronary artery bypass grafting (OPCABG) and pulmonary resection for lung cancer. PATIENT CONCERNS Between 2014 and 2016, 5 patie...
متن کاملOff-Pump Versus On-Pump Coronary Artery Bypass Graft Surgery, prospective cohort study
Introduction: Coronary artery bypass grafting is a surgical operation that bypasses atherosclerotic coronary vessels and restores blood flow to the ischemic zone of hearts. And two different conventional methods are ON-pump CABG, and Off-pump CABG. Altogether, the efficacy and safety of these two types of surgical procedures are still under debate. In this study, we aim to com...
متن کاملMonitoring brain oxygen saturation during awake off-pump coronary artery bypass.
OBJECTIVE To evaluate the changes in cerebral blood flow during awake off-pump coronary artery bypass grafting and compare with the changes during off-pump coronary artery bypass grafting under general anesthesia, using continuous monitoring of regional cerebral oxygen saturation. METHODS The study population comprised 3 groups of patients who had undergone off-pump coronary artery bypass gra...
متن کاملAvoidance of Dialysis in an End-Stage Renal Disease Patient Status-post Off-pump Coronary Artery Bypass Grafting
Certain benefits are clearly associated with the use of off-pump coronary artery bypass grafting (CABG) as compared with the on-pump CABG. The superiority is more evident in patients with multiple co morbidities including renal failure.We reviewed the medical records of a 67-year-old male with a past medical history that was significant for multiple cardiovascular diseases and new-onset end-sta...
متن کاملDescending aortic pulsed wave Doppler can predict changes in cardiac output during off-pump coronary artery bypass surgery.
Retraction and stabilization of the heart can induce rapid and large changes in the hemodynamic state during off-pump coronary artery bypass graft surgery (OPCABG). We aimed to determine if Doppler measurement of flow in the descending artery with transesophageal echocardiography (TEE) can provide a beat-to-beat assessment of changes in cardiac output (CO) in 26 OPCABG patients. Simultaneous me...
متن کامل