Improving spatial resolution in SPECT with the combination of PSPMT based detector and iterative reconstruction algorithms.
نویسندگان
چکیده
This paper investigates the possibility of developing a SPECT system that combines the high spatial resolution of position sensitive photomultiplier tubes (PSPMTs) with the excellent performance of iterative reconstruction algorithms. A small field of view (FOV) camera based on a PSPMT and a pixelized scintillation crystal made of CsI(Tl) have been used for the acquisition of the projections. With the use of maximum likelihood expectation maximization (ML-EM) and ordered subsets expectation maximization (OSEM) slices of the object are obtained while three-dimensional (3D) reconstruction of the object is carried out using a modified marching cubes (MMC) algorithm. The spatial resolution of tomographic images obtained with the system was 2-3mm. The spatial resolution of a conventional system that uses filtered backprojection (FBP) for slices reconstruction was more than 9 mm.
منابع مشابه
Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system
Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...
متن کاملA model based, anatomy dependent method for ultra-fast creation of primary SPECT projections
Introduction: Monte Carlo (MC) is the most common method for simulating virtual SPECT projections. It is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of MC is its long run time. We introduced a model based method considering the eff...
متن کاملCollimator-detector response compensation in molecular SPECT reconstruction using STIR framework
Introduction:It is well-recognized that collimator-detector response (CDR) is the main image blurring factor in SPECT. In this research, we compensated the images for CDR in molecular SPECT by using STIR reconstruction framework. Methods: To assess resolution recovery capability of the STIR, a phantom containing five point sources along with a micro Derenzo p...
متن کاملEvaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملEvaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom
Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
دوره 27 4 شماره
صفحات -
تاریخ انتشار 2003