Development of a compact mouse MRI using a yokeless permanent magnet.
نویسندگان
چکیده
A compact mouse MRI has been developed using a 1.0T yokeless permanent magnet and portable MRI console. The entire system was installed in a space measuring 2 m x 1 m. The imaging region was the cylindrical volume (35 mm diameter, 50 mm length) at the center of the magnet and was used for whole-brain or body imaging of mice. Whole-brain imaging took less than 90 min for T1- and T2-weighted 3D images with 2-mm slice thickness and 200-microm in-plane resolution. Body imaging took less than 30 min for T1-weighted spin-echo and FLASH 3D images with 0.5- to 1.0-mm slice thickness and 250- to 300-microm in-plane resolution. In addition to the compactness of the system, the mouse MRI has several advantages over high-field superconducting animal MRI systems in its accessibility to the specimen, similarity to clinical MRI in image contrast, capacity for biological isolation, and maintenance. The results obtained demonstrate the potential of this new system for routine imaging in biomedical laboratories.
منابع مشابه
Hybrid Fuzzy Algorithm for the Novel Yokeless Axial Flux-Switching Permanent-Magnet Motor
Flux switching permanent magnet synchronous motor (FMSM) has the characteristics such as large output torque, fast speed response and high reliability, so it can be widely used in the field of high-performance and high precision control.In the permanent magnet synchronous motor control system, the speed loop usually adopts the PI control algorithm. Although the PI control algorithm is relativel...
متن کاملHigh resolution NMR imaging using a high field yokeless permanent magnet.
We measured the homogeneity and stability of the magnetic field of a high field (about 1.04 tesla) yokeless permanent magnet with 40-mm gap for high resolution nuclear magnetic resonance (NMR) imaging. Homogeneity was evaluated using a 3-dimensional (3D) lattice phantom and 3D spin-echo imaging sequences. In the central sphere (20-mm diameter), peak-to-peak magnetic field inhomogeneity was abou...
متن کاملDevelopment of a compact MRI system for trabecular bone microstructure measurements of the distal radius.
A compact MRI system for trabecular bone (TB) microstructure measurements of the distal radius was developed using a 1.0 T permanent magnet and a compact MRI console. TB microstructure of the distal radius was clearly visualized using a three-dimensional (3D) driven equilibrium spin-echo (DESE) sequence in 23 min. The image obtained had a sufficient spatial resolution (150 microm x 150 microm x...
متن کاملField-Weakening Performance Improvement of the Yokeless and Segmented Armature Axial Flux Motor for Electric Vehicles
In order to avoid the unsafe operation and raise efficiency of yokeless and segmented armature axial flux motors at high speed, the control current of air gap flux is expected to be as small as possible with the same field-weakening effect. To reduce the control complexity, a new structure of module poles with a combination of permanent magnet and soft magnetic material is proposed, which has t...
متن کاملDevelopment of the 1.2 T~1.5 T Permanent Magnetic Resonance Imaging Device and Its Application for Mouse Imaging
By improving the main magnet, gradient, and RF coils design technology, manufacturing methods, and inventing new magnetic resonance imaging (MRI) special alloy, a cost-effective and small animal specific permanent magnet-type three-dimensional magnetic resonance imager was developed. The main magnetic field strength of magnetic resonance imager with independent intellectual property rights is 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine
دوره 4 3 شماره
صفحات -
تاریخ انتشار 2005