Comparative accuracy of real-time myocardial contrast perfusion imaging and wall motion analysis during dobutamine stress echocardiography for the diagnosis of coronary artery disease.
نویسندگان
چکیده
OBJECTIVE This study sought to compare the accuracy of myocardial contrast echocardiography (MCE) and wall motion analysis (WMA) during submaximal and peak dobutamine stress echocardiography (DSE) for the diagnosis of coronary artery disease (CAD). BACKGROUND The relative merits of MCE and WMA for the detection of CAD during DSE have not been studied in a large number of patients. METHODS We studied 170 patients who underwent dobutamine (up to 50 microg/kg/min)-atropine stress testing and coronary angiography. The WMA and MCE (using repeated boluses of Optison [Mallinckrodt, St. Louis, Missouri] or Definity [Bristol-Myers Squibb, New York, New York]) were performed at rest, at intermediate stress (65% to 75% of maximal heart rate), and at peak stress. The diagnosis of CAD (>/=50% stenosis in >/=1 coronary artery) was based on reversible wall motion and perfusion abnormalities. RESULTS Coronary artery disease was detected in 127 (75%) patients. Sensitivity of MCE was higher than that of WMA at maximal stress (91% vs. 70%; p = 0.001) and at intermediate stress (84% vs. 20%; p = 0.0001). Specificity was lower for MCE compared with WMA (51% vs. 74%; p = 0.01). Overall accuracy was higher for MCE than for WMA (81% vs. 71%; p = 0.01). Sensitivity for detection of CAD based on abnormalities in >/=2 vascular regions was higher for MCE than for WMA (67% vs. 28%; p < 0.01). CONCLUSIONS The majority of inducible perfusion abnormalities occur at an intermediate phase of the stress test, without wall motion abnormalities. Myocardial contrast echocardiography provides better sensitivity than WMA, particularly in patients with submaximal stress and in identifying patients with multivessel CAD.
منابع مشابه
Serial imaging and histology illustrating the degradation of a bioabsorbable magnesium stent in a porcine coronary artery.
Cardiol 2004;43:257–264. 72. Jeetley P, Hickman M, Kamp O, Lang RM, Thomas JD, Vannan MA, Vanoverschelde JL, Wouw van der PA, Senior R. Myocardial perfusion assessment in patients with medium probability of coronary artery disease and no prior myocardial infarction: comparison of myocardial contrast echocardiography with 99mTc single-photon emission computed tomography. Am Heart J 2004;147: 110...
متن کاملSafety of dobutamine stress real-time myocardial contrast echocardiography.
OBJECTIVES The aim of this study was to determine the safety of dobutamine stress myocardial perfusion imaging (MPI) obtained by real-time contrast echocardiography (RTCE) and intravenous ultrasound contrast in a large cohort of patients with suspected coronary artery disease (CAD). BACKGROUND Despite the increasing number of studies showing the potential clinical utility of myocardial contra...
متن کاملPrognostic value of dobutamine stress myocardial contrast perfusion echocardiography.
BACKGROUND Myocardial perfusion (MP) imaging with real-time contrast echocardiography (RTCE) improves the sensitivity of dobutamine stress echocardiography for detecting coronary artery disease. Its prognostic value is unknown. We sought to determine the value of MP and wall motion (WM) analysis during dobutamine stress echocardiography in predicting the outcome of patients with known or suspec...
متن کاملReal-time perfusion adenosine stress echocardiography versus myocardial perfusion adenosine scintigraphy for the detection of myocardial ischaemia in patients with stable coronary artery disease.
BACKGROUND Real-time perfusion (RTP) contrast echocardiography using low mechanical index power modulation technique allows for simultaneous myocardial perfusion and wall motion analysis. RTP-adenosine stress echocardiography (ASE) could be an alternative to dobutamine-atropine stress echocardiography; more tolerable for the patients and possibly similarly accurate. We aimed to evaluate RTP-ASE...
متن کاملDetection of subendocardial ischemia in the left anterior descending coronary artery territory with real-time myocardial contrast echocardiography during dobutamine stress echocardiography.
OBJECTIVES The purpose of this study was to test whether the transmural delineation of myocardial perfusion during dobutamine stress imaging with real-time myocardial contrast echocardiography (RTMCE) might permit visualization of dobutamine-induced subendocardial ischemia. BACKGROUND Significant coronary artery disease can be present despite normal transmural wall thickening (WT) responses d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 44 11 شماره
صفحات -
تاریخ انتشار 2004