Ten year clinical evaluation of Starr-Edwards 2400 and 1260 aortic valve prostheses.
نویسندگان
چکیده
The long term performance characteristics of the 2400 and 1260 series of Starr-Edwards aortic prostheses were investigated by a follow up study of clinical outcome of 327 patients discharged from hospital with isolated aortic valve replacement. Follow up lasted for up to 10 years and was based on 1616 patient-years. The 2400 series cloth covered tracked valve was implanted in 182 patients from 1974 to 1980 and the 1260 series bare strut silastic ball valve was inserted in 145 patients from 1979 to 1983. Total 10 year mortality and valve related morbidity were low and no cases of mechanical valve failure were recorded. There were no significant actuarial differences in mortality or valve related morbidity between the 2400 and 1260 valves. Starr-Edwards models 2400 and 1260 aortic valve prostheses showed excellent durability without any mechanical failures over a 10 year period. The long term outcome of isolated aortic valve replacement with these models is associated with a low frequency of valve related complications.
منابع مشابه
Ten year clinical evaluation of Starr - Edwards 2400 and 1260 aortic valve
The long term performance characteristics of the 2400 and 1260 series of StarrEdwards aortic prostheses were investigated by a follow up study of clinical outcome of 327 patients discharged from hospital with isolated aortic valve replacement. Follow up lasted for up to 10 years and was based on 1616 patient-years. The 2400 series cloth covered tracked valve was implanted in 182 patients from 1...
متن کاملReplacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.
A 53-year-old woman who had undergone aortic valve replacement with a Starr-Edwards (S-E) valve (Model 1260) and open mitral commissurotomy 28 years previously was hospitalized with cardiac failure. Echocardiography showed mitral stenosis, mitral regurgitation, and a normally functioning S-E prosthesis. At reoperation, the mitral and aortic valves were replaced with St Jude bileaflet mechanical...
متن کاملDouble Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.
Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...
متن کاملIntravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.
Seventy-four patients with single prosthetic valves (Björk-Shiley or Starr-Edwards) in the mitral or aortic position and 18 controls with rheumatic valvar heart disease were investigated for evidence of intravascular haemolysis. Serum lactate dehydrogenase (LDH) was used as the most sensitive indicator of haemolysis. Raised concentrations were found in a third of 39 patients with Björk-Shiley p...
متن کاملPlatelet survival time following aortic valve replacement.
Thromboembolism continues to complicate the course of patients following aortic valve replacement. In patients with prosthetic and homograft mitral valves, platelet survival time has been shown to correlate with occurrence of thromboembolism. This study extends these observations to patients with aortic valve disease. Platelet survival time was measured (by the chromium-51 method) in 73 patient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 57 4 شماره
صفحات -
تاریخ انتشار 1987