A new technique of fixation of radial head fractures using a modified tubular plate.
نویسندگان
چکیده
Radial head fractures are fairly common, occurring in 17-44% of all elbow injuries. Mason Type 2 fractures may be fixed using mini fragment screws, this fixation often needing augmentation with a plate to make the construct rotationally stable. However, the drill holes needed to fix the plate to the radial head, carry the risk of inflicting more injury to the fractured fragments. In our case, the radial head fracture was fixed with a modified one-third tubular plate. The plate was cut through the distal hole and the two cut ends were bent into hooks. These two hooks were engaged into two breaches made on the margin of the radial head and this provided rotational stability to the head without causing further damage. The fracture healed well and the patient regained full movement in the elbow. We conclude that this method may be used to fix fractures of the radial head, which require additional support with a plate.
منابع مشابه
The Best Option in Treatment of Modified Mason Type III Radial Head Fractures: Open Reduction and Internal Fixation Versus Radial Head Excision
Background: Radial head fractures commonly occur during elbow traumas. Among those, treatment of Mason type IIIfractures is still under controversy. Common treatment methods for these fractures include open reduction and internalfixation (ORIF) as well as radial head excision. In this study, we compared long-term outcomes of both methods intreatment of patients with Mason type III fractures of ...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملComparison of crossed screw versus plate fixation for radial neck fractures.
BACKGROUND Fixation of radial neck fractures can be achieved with a plate and screw construct or, in absence of comminution, with two obliquely-oriented screws. This study investigated the mechanical properties, specifically the stiffness and load to failure, of these two fixation strategies in a cadaver model. METHODS Ten matched-pair radii were removed from fresh cadaver arms. A transverse ...
متن کاملAcute unstable complex radial head and neck fractures fixed with a mini T-shaped plate in a 20-year-old man: a case report
Acute unstable complex radial head and neck fractures in adults are seldom reported in the literature. Early recognition and appropriate management are essential to prevent long-term consequences of the loss of elbow function, forearm rotation, and chronic pain. Here, we describe an unusual case of a 20-year-old man who exhibited acute unstable complex fractures of the head and neck of the righ...
متن کاملEvaluation of Radiocapitellar Arthritis in Patients with a Second Radiograph at Least 2 Years after Nonoperative Treatment of an Isolated Radial Head Fracture
Background: To study if patients that have a second radiograph 2 or more years after nonoperative treatment of an isolated radial head fracture have radiocapitellar osteoarthritis (RC OA). Methods: We used the database of 3 academic hospitals in one health system from 1988 to 2013 to find patients with isolated radial head fractures (no associated ligament injury or fracture) that had a second ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of postgraduate medicine
دوره 50 2 شماره
صفحات -
تاریخ انتشار 2004