Design modifications of high-flexion TKA do not improve short term clinical and radiographic outcomes

نویسندگان

  • Jai Gon Seo
  • Young-Wan Moon
  • Moon Jong Chang
  • Byung Chul Jo
  • Yong Beom Park
  • Deuk Soo Lim
  • Byung Hoon Lee
چکیده

BACKGROUND The prosthesis of contemporary total knee arthroplasty (TKA) has been modified to provide a more familiar environment for higher flexion angle of the replaced knee. The design modifications continue based on evidence reported in the literature. However, whether these modifications of the prosthesis design lead to improvements in clinical results needs further investigation. We determined whether the prosthesis modifications based on recent evidence improve clinical and radiographic results following high flexion TKA. METHODS 524 patients who underwent primary TKA using two different high flexion prostheses were divided to Group 1 (HF-1) using a high flexion prosthesis, group 2 (HF-2) using the more recently devised high flexion prosthesis, which claims to be adopted from evidence proposed in the literature. Clinical outcomes included ranges of motion (ROM), the Knee Society knee and function score (KSKS and KSFS), the Western Ontario and McMaster Universities Arthritis Index (WOMAC) score, radiologic evaluation, and complication related to surgery. RESULTS No differences in terms of clinical and radiographic results were observed between the groups at the 2 year follow-up. The mean ROM was 123°and 124° in the HF-1 and HF-2 groups, respectively. KSKS were 90 and 89.1, KSFS were 76.6 and 81.8, and total WOMAC scores were 23.1 and 24.9 in the HF-1 and HF- 2 groups. No differences of the incidences of radiolucency on radiographs (1.4% in HF-1, 2.1% in HF-2) and dislocation (1 case in HF-1 only) was observed. CONCLUSIONS Even if recent modifications in the design of high flexion TKA prosthesis were based on evidence in the literature, they did not provide meaningful improvements in short-term clinical and radiographic outcomes after TKA. Surgeons should consider our findings when choosing a prosthesis for their patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Outcomes of the Different Types of Total Knee Arthroplasty with the Identical Femoral Geometry

PURPOSE There are controversies around the role of the posterior cruciate ligament and the effect of design modifications for high flexion in total knee arthroplasty (TKA). So, we compared the clinical outcomes of the cruciate retaining (CR), posterior stabilized (PS), and high flexion posterior stabilized (F-PS) designs in TKA with identical femoral geometry. MATERIALS AND METHODS One hundre...

متن کامل

Comparison of Clinical Results between Patellar Resurfacing and Non-resurfacing in Total Knee Arthroplasty: A Short Term Evaluation

Background: There is no difference in the functional outcomes 6 months after total knee arthroplasty (TKA) for kneeosteoarthritis between patellar resurfacing and non-resurfacing. Thus, we have performed this study to compare theshort-term clinical outcomes of TKA performed with and without the patella resurfacing.Methods: A total of 50 patients with osteoarthritis of the knee (OAK) were random...

متن کامل

Outcome and range of motion using a high-flexion cruciate-retaining TKA.

Increased knee flexion after total knee arthroplasty (TKA) may contribute to patients' increased satisfaction and more active lifestyles. This study evaluated a TKA component designed for high flexion (more than 125°). The design features an anatomic sagittal femoral radius with short, flared femoral condyles to allow for femoral rollback. Fifty TKA procedures in 47 patients were evaluated pros...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014