Ditanet Contributing to State-of-the-art Diagnostics Developments
نویسنده
چکیده
DITANET is the largest-ever EU funded training network in beam diagnostics. The network members universities, research centers and industry partners are developing diagnostics methods for a wide range of existing or future particle accelerators, both for electron and ion beams. This is achieved through a cohesive approach that allows for the exploitation of synergies, whilst promoting knowledge exchange between partners. In addition to its broad research program, the network organizes schools and topical workshops for the beam instrumentation community. This contribution gives an overview of the Network's research portfolio, summarizes the main research results from the first two years of DITANET and presents past and future training activities.
منابع مشابه
Low Energy Beam Diagnostics Developments within Ditanet
Low energetic ion beam are very attractive for a large number of fundamental physics experiments. The development of beam instrumentation for such beams poses many challenges due to the very low currents down to only a few thousands of particles per second and the resulting very low signal levels. Within DITANET, several institutions aim at pushing low energy, low intensity diagnostics beyond t...
متن کاملDitanet - an International Network in Beam Diagnostics
Beam diagnostics systems are essential constituents of any particle accelerator; they reveal the properties of a beam and how it behaves in a machine. Without an appropriate set of diagnostic elements, it would simply be impossible to operate any accelerator complex, let alone optimize its performance. Beam diagnostics is also a rich field in which a great variety of physical effects are made u...
متن کاملField effect transistor nanobiosensors: State-of-the-art and key challenges as point of care testing devices
The existing health care systems focus on treating diseases rather than preventing them. Patients are generally not tested unless physiological symptoms are appeared. When they do get tested, the results often take several days and can be inconclusive if the disease is at an early stage. In order to facilitate the diagnostics process and make tests more readily available for patients, the conce...
متن کاملDitanet - Investigations into Accelerator Beam Diagnostics
DITANET is a Marie Curie initial training network in beam diagnostics. The network members, universities, research centers and industry partners, are developing diagnostics methods for a wide range of existing or future particle accelerators, both for electron and for ion beams. This is achieved through a cohesive approach that allows for the exploitation of synergies, whilst promoting knowledg...
متن کاملColloids: Applications and Remaining Challenges
Using of colloids and polymeric microparticles are gradually increasing. It is observed that the positive effects of particles stems in both traditional applications such as column pickings, coatings and paints to more recent technologies in diagnostics, drug delivery and optical devices are well documented. This review focuses on importance of colloids and covers their applications on three le...
متن کامل