The i-gel Supraglottic Airway as a Conduit for Fibreoptic Tracheal Intubation - A Randomized Comparison with the Single-use Intubating Laryngeal Mask Airway and CTrach Laryngeal Mask in Patients with Predicted Difficult Laryngoscopy.

نویسندگان

  • Pavel Michálek
  • Will Donaldson
  • Francis McAleavey
  • Alexander Abraham
  • Rachel J Mathers
  • Claire Telford
چکیده

Fibreoptic intubation through a supraglottic airway is an alternative plan for airway management in difficult or failed laryngoscopy. The aim of this study was to compare three supraglottic airways as conduits in patients with at least one predictor for difficult laryngoscopy. The i-gel was compared with the single-use intubating laryngeal mask airway (sILMA) and CTrach laryngeal mask in 120 adult patients scheduled for elective surgeries under general anaesthesia using a prospective, randomized and single-blinded design. Primary outcome was success rate of tracheal intubation through the device, while secondary outcomes were times required for device insertion and tracheal tube placement, fibreoptic scores and the incidence of perioperative complications and postoperative complaints. The success rates showed no statistical difference between devices (i-gel 100%, CTrach 97.5%, ILMA 95%). Insertion time was shortest for the i-gel (12.4 s) compared with ILMA (19.3 s) and CTrach (24.4 s). Intubation time was shorter in the i-gel group (29.4 s) in comparison with the CTrach (39.8 s, p<0.05) and sILMA (51.9 s, p<0.001) groups. Best fibreoptic scores were observed also in the i-gel group. In total, 24 patients (20%) presented with difficult laryngoscopy. The i-gel showed significantly shorter times for insertion and fibreoptic intubation than the other two devices in this group. No difference was observed in the incidence of postoperative complaints. The i-gel is a suitable alternative to the sILMA and CTrach for fibrescope-guided tracheal intubation. Shorter insertion and intubation times with the i-gel may provide advantage in case of difficult oxygenation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Endotracheal Intubation Through I-gel and Intubating Laryngeal Mask Airway

Received: February 11, 2016 Revised: June 24, 2016 Accepted: June 24, 2016 Abstract: Background: Supraglottic airway devices (SADs) are very useful airway adjunct in managing anticipated and unanticipated difficult airway and can be used as a ventilating aid and as a conduit for tracheal intubation. The new versions of SADs like i-gel and intubating laryngeal mask airway (ILMA), have advantage ...

متن کامل

Success of tracheal intubation with intubating laryngeal mask airways: a randomized trial of the LMA Fastrach and LMA CTrach.

BACKGROUND The LMA CTrach system (The Laryngeal Mask Company, Singapore) is a development of the LMA Fastrach system (The Laryngeal Mask Company, Singapore), with integrated fiberoptic bundles and a detachable liquid crystal display viewer. This randomized study of 271 patients compared tracheal intubation with these two systems. METHODS In both groups, ventilation was optimized after inserti...

متن کامل

Use of a laryngoscope, held sideways, as an aid in perforsming an intraoral glossopharyngeal nerve block

A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: A manikin study.

متن کامل

The new air-Q intubating laryngeal airway for tracheal intubation in children with anticipated difficult airway: a case series.

The air-Q intubating laryngeal airway (ILA) is a new supraglottic airway device which may overcome some limitations inherent to the classic laryngeal mask airway for tracheal intubation. We present a case series of patients with anticipated difficult airway in whom the air-Q ILA was successfully used as a conduit for fiberoptic intubation.

متن کامل

Sedation of children undergoing magnetic resonance imaging.

of morbidly obese patients: LMA CTrach vs direct laryngoscopy. Br J Anaesth 2006; 97: 742–5 2 Liu EHC, Goy RWL, Chen FG. The LMA CTrach, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients. Br J Anaesth 2006; 96: 396–400 3 Timmermann A, Russo S, Graf BM. Evaluation of the CTrach— an intubating LMA with integrated fibreoptic system. Br J Anaesth 2006;...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Prague medical report

دوره 117 4  شماره 

صفحات  -

تاریخ انتشار 2016