Rarebit perimetry and frequency doubling technology in patients with ocular hypertension.
نویسندگان
چکیده
PURPOSE To test the capability of rarebit perimetry (RP), a recent non-conventional perimetric technique, in detecting early functional damage in subjects with ocular hypertension (OHT) and to compare RP findings with those obtained by frequency-doubling technology (FDT) perimetry. METHODS Thirty patients with OHT were matched with 30 healthy subjects. All were tested with RP and FDT. Frequency-doubling technology mean deviation (MD) and pattern standard deviation (PSD), as well as RP mean hit rate (MHR), of the two groups were analyzed. The agreement between the two techniques was tested by Kappa analysis. RESULTS In the OHT group the mean (SD) FDT MD was 0.5 (2.1), the mean (SD) FDT PSD was 4.2 (1.6), and the mean (SD) RP MHR was 81.4 (6.7). In the control group, corresponding values were mean (SD) FDT MD 1.1 (1.4), mean (SD) FDT PSD 3.0 (0.3), mean (SD) RP MHR 96.2 (2.0). The differences between the two groups were not significant for the studied indexes. Eleven (36.6%) out of the 30 OHT eyes had abnormal RP results; 12 (40.0%) eyes had abnormal FDT results. Five (16.6%) eyes had abnormal RP and FDT findings. Only 1 eye (3.3%) in the control group had abnormal RP results and 3 eyes (10.0%) had abnormal FDT results. RP and FDT showed a moderate agreement (Kappa=0.43; 95% CI: 0.42 to 0.51). CONCLUSIONS RP and FDT showed VF defects not shown in standard automated perimetry in the OHT group. This may be indicative of an increased risk in developing glaucoma, even if a gold standard for detecting subtle defects is not currently available. RP has the additional advantage of not requiring any expensive device to be used. The poor agreement between these techniques in identifying eyes with early damage warrants further investigations. Large longitudinal studies are needed before defining the role of RP in early glaucoma diagnosis.
منابع مشابه
Learning effect of humphrey matrix frequency doubling technology perimetry in patients with ocular hypertension.
AIM To evaluate the learning effect of Frequency Doubling Technology (FDT) perimetry using the Humphrey Matrix-FDT perimetry (Matrix) 24-2 full-threshold program on patients with ocular hypertension experienced with standard automated perimetry. METHODS Twenty-four patients with ocular hypertension underwent 5 full-threshold Matrix tests at intervals of 5+/-2 days. Learning effect was defined...
متن کاملFrequency Doubling Technology vs Standard Automated Perimetry in Ocular Hypertensive Patients
BACKGROUND Frequency doubling technology (FDT) perimetry measures contrast sensitivity. The magnocellular component of ganglion cells in human retina is isolated as a whole by the FDT stimulus. The aim of this study is to investigate the role of Humphrey Matrix threshold testing in the detection of early functional retinal impairment in ocular hypertensive patients compared to standard automate...
متن کاملVisual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.
PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...
متن کاملProbing glaucoma visual damage by rarebit perimetry.
AIM To compare rarebit perimetry (RBP) with standard achromatic perimetry (SAP) in detecting early glaucomatous functional damage. METHODS 43 patients with ocular hypertension (OH), 39 with early primary open angle glaucoma (POAG), and 41 controls were considered. Visual fields were assessed using the Humphrey field analyser (HFA) 30-2 and RBP tests. Differences among the groups were evaluate...
متن کاملDetection of early visual field loss in glaucoma using frequency-doubling perimetry and short-wavelength automated perimetry.
OBJECTIVE To investigate whether frequency-doubling perimetry (FDP) predicts future visual field loss with achromatic automated perimetry (AAP), just as it may be predicted with short-wavelength automated perimetry (SWAP). METHODS We recruited 62 patients selectively from an urban glaucoma practice. At the commencement of the study, each patient had ocular hypertension with normal visual fiel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of ophthalmology
دوره 18 2 شماره
صفحات -
تاریخ انتشار 2008