Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws

نویسندگان

  • Chang Hyun Oh
  • Seung Hwan Yoon
  • Yongjung J. Kim
  • Dongkeun Hyun
  • Hyeong-Chun Park
چکیده

OBJECTIVE A variety of different pedicle screws entry point techniques are used for the lumbar pedicle screws placement. This study reported Kim's entry point of lumbar pedicle screws with free hand technique and the accuracy of this technique. METHODS We retrospectively reviewed the 584 cases with free hand placed lumbar pedicle screw placement. The diagnosis included 491 cases with degenerative spine, 59 cases with trauma, 29 cases with metastatic disease, and 5 cases with scoliosis. A total of 2601 lumbar pedicle screws were placed, and the entry points of lumbar pedicle screws were the junction of proximal edge of transverse process and lamina. Incidence and extent of cortical breach by misplaced pedicle screw was determined by review of intra-operative and post-operative radiographs and/or computed tomography. RESULTS Among the total 2601 lumbar free hand placed pedicle screws, 114 screws (4.4%) in 79 patients (13.5%) were repositioned screws with suspected screw malposition during operation, and 37 screws (1.4%) in 31 patients (5.3%) were identified as moderate to severe breaching the pedicle after post-operative imaging studies. Among the patient with malpositioned screws, 3 patients showed nerve irritation sign of the lesion, and 2 cases were symptom improved after nerve block and conservative management, and 1 case was removed the screw after the failure of the treatment. CONCLUSION Free hand pedicle screw placement based on external landmark with the junction of proximal edge of transverse process and lamina showed acceptable safety and accuracy and avoidance of radiation exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Incidence and Risk Factors of Adjacent Cranial Facet Joint Violation Following Pedicle Screw Insertion Using Cortical Bone Trajectory Technique.

STUDY DESIGN Retrospective study evaluating cranial facet joint violation (FJV) by pedicle screws. OBJECTIVE The aim of the study was to determine the incidence and risk factors of FJV following screw placement via cortical bone trajectory (CBT). SUMMARY OF BACKGROUND DATA CBT is a new minimally invasive technique for lumbar pedicle screw insertion that minimizes muscle dissection. Insertin...

متن کامل

Translaminar Facet Screw Fixation

Introduction Lumbar fusion has proven to be an accepted treatment for a variety of indications. Pedicle screw fixation has historically been the gold standard for providing stabilization to the lumbar motion segment while the fusion matures. However, numerous studies have reported high complication rates, increased pain, and juxtalevel degeneration due to the size of the pedicle screw instrumen...

متن کامل

Accuracy of Free Hand Pedicle Screw Installation in the Thoracic and Lumbar Spine by a Young Surgeon: An Analysis of the First Consecutive 306 Screws Using Computed Tomography

STUDY DESIGN A retrospective cross-sectional study. PURPOSE The purpose of this study is to evaluate the accuracy and safety of free-hand pedicle screw insertion performed by a young surgeon. OVERVIEW OF LITERATURE Few articles exist regarding the safety of the free-hand technique without inspection by an experienced spine surgeon. METHODS The index surgeon has performed spinal surgery fo...

متن کامل

Free-hand placement of high thoracic pedicle screws with the aid of fluoroscopy: evaluation of positioning by CT scans in a four-year consecutive series.

OBJECTIVE To evaluate the feasibility, safety and accuracy of pedicle screw placement in the upper thoracic spine using the free-hand technique with the aid of fluoroscopy; to analyze the methods used to verify correct screw positioning intra and postoperatively. METHOD All patients with instability of the cervicothoracic or upper thoracic spine and at least one screw placed in the segment T1...