Electromagnetic Probes
نویسنده
چکیده
A review is presented of dilepton and real photon measurements in relativistic heavy ion collisions over a very broad energy range from the low energies of the BEVALAC up to the highest energies available at RHIC. The dileptons cover the invariant mass range ml+l− = 0 2.5 GeV/c, i.e. the continuum at low and intermediate masses and the light vector mesons, ρ, ω, φ. The review includes also measurements of the light vector mesons in elementary reactions.
منابع مشابه
بررسی عملکرد پروبهای UHF در آشکارسازی تخلیه جزئی در ترانسفورماتورهای فشار قوی
Recently, UHF partial discharge (PD) detection on power transformers attracts lots of attentions. For the transformers already installed in power network, the UHF signals can be captured only by UHF probes installed through oil drain valve. Although UHF probes are commercially produced, there are a lot of missing information on characteristics and features of these probes for PD detection. In t...
متن کاملA New Antenna Calibration Method and a Selection of Ameasurement Probe with Minimal Disturbance and Sufficientsensitivity for Electromagnetic Exposure Measurements Aroundwireless Base Stations
To measure electromagnetic fields accurately, the calibration of field probes is necessary. In this paper, an accurate lowcost calibration method is presented. However, calibration does not take into account all influencing factors, especially when measuring fields close to the source (e.g., antenna). While measuring, the electromagnetic field will be disturbed by the measurement probes themsel...
متن کاملEMC’04/Sendai INVASIVENESS OF OPTICAL MAGNETIC FIELD PROBES WITH A LOOP ANTENNA ELEMENT
Electromagnetic field probes inevitably change the original field distribution to some extent when they are positioned close to a device. That change affects measurement accuracy and the device operation. We have developed optical magnetic field probes, which comprise a loop antenna element and an electro-optic crystal, to perform magnetic nearfield measurement with high accuracy in the GHz fre...
متن کاملDileptons and Open Charm: Probes of Chiral Restoration K. Gallmeister, B. Kämpfer and S. Zschocke
(2) where 〈〈· · ·〉〉means the thermal average with respect to the medium with temperature T and baryon density n; Jμ is the electromagnetic current operator. Also the real photon emission rate is related to ImΠμν . Therefore, the electromagnetic probes are sensitive to the medium properties. Since the absorption probability of such probes, once emitted, is small they carry information on the ful...
متن کاملUsing Capacitive Probes in Electromagnetic Nondestructive Testing
In an attempt to expand the scope of electromagnetic testing to include poorly conducting materials, we have tried using a low frequency capacitive probe. This probe has given promising performances in testing materials with resistivities of several hundred ohm-centimeters.
متن کاملValidation of Two Flow Probes Using Bovine , Porcine , Ovine and Human Blood
In-line electromagnetic and doppler flow probes employed in extracorporeal circuits are calibrated for use with human blood. This study was performed to compare the accuracy of the Sarns Delphin II Doppler and the Medtronic Bio-Medicus electromagnetic flow probes to actual flow using bovine, porcine, ovine and human blood. The flow probes were incorporated into an in vitro extracorporeal circui...
متن کامل