End-systolic pressure-volume relation estimated from physiologically loaded cat papillary muscle contractions.
نویسندگان
چکیده
Sherman H (1960) On the theory of indicator dilution methods under varying blood flow conditions. Bull Math Biophys 22: 417-424 Stephenson JL (1948) Theory of the measurement of blood flow by the dilution of an indicator. Bull Math Biophys 10: 117121 Stewart GN (1898) Researches on the circulation time and on the influences which affect it. IV. The output of the heart. J Physiol Lond 22: 159-183 Swan HJ, Beck W (1960) Ventricular non-mixing as a source of error in the estimation of ventricular volume by the indicatordilution technique. Circ Res 8: 989-998 Zierler KL (1962) Theoretical basis of indicator-dilution methods for measuring flow and volume. Circ Res 10: 393-407 Zierler KL (1965) Equations for measuring blood flow by external monitoring of radioisotopes. Circ Res 16: 309-321
منابع مشابه
Isometric relaxation of rat myocardium at end-systolic fiber length.
In a "physiologically sequenced" contraction (PSC), which loads the isolated muscle preparation in a manner which approximates that of the intact heart, isometric relaxation precedes isotonic relaxation and occurs at minimum ("end-systolic") length. We studied the effects of inital muscle length, load, temperature, calcium, and isoproterenol on the isometric relaxation phase of physiologically ...
متن کاملHeat released during relaxation equals force-length area in isometric contractions of rabbit papillary muscle.
It has been claimed that the mechanical performance and the related energy turnover of the left ventricle can be reliably predicted on the basis of its time-varying elastance behavior. In its most elementary form, this behavior can be mathematically described by E(t) = P(t)/[V(t)-Vd], where E is ventricular elastance, t is time, P is ventricular pressure, V is ventricular volume, and Vd is the ...
متن کاملPhysiological loading of isolated feline cardiac muscle. The interaction between muscle contraction and vascular impedance in the production of pressure and flow waves.
Isolated cat papillary muscle preparations were assumed to contract in the wall of a hypothetical cylindrical model of the left ventricle ejecting into a vascular impedance. Using analogcomputing techniques, a feedback system was created between shortening, velocity of shortening, and the load on the muscle. This feedback function could be modulated by altering the resistance and capacitance co...
متن کاملSensitivity of end-systolic pressure-dimension and pressure-volume relations to the inotropic state in humans.
The value for the slope of the left ventricular (LV) end-systolic pressure-dimension and pressure-volume relations has been proposed as a quantitative measure of the LV inotropic state. This measure of LV inotropic state is attractive because it is independent of preload and incorporates afterload. To investigate the sensitivity of the slope of these relations to alterations in contractile stat...
متن کاملSingle cell mechanics of rat cardiomyocytes under isometric, unloaded, and physiologically loaded conditions.
One of the most salient characteristics of the heart is its ability to adjust work output to external load. To examine whether a single cardiomyocyte preparation retains this property, we measured the contractile function of a single rat cardiomyocyte under a wide range of loading conditions using a force-length measurement system implemented with adaptive control. A pair of carbon fibers was u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 47 1 شماره
صفحات -