Comparing two methods for assessment of perfusion-diffusion mismatch in a rodent model of ischaemic stroke: a pilot study.

نویسندگان

  • F Chen
  • Q Liu
  • H Wang
  • Y Suzuki
  • N Nagai
  • J Yu
  • G Marchal
  • Y Ni
چکیده

This stroke experiment was designed to define the mismatch between perfusion-weighted imaging (PWI) and diffusion-weighted imaging (DWI) in MRI by applying early or instantly acquired PWI. Eight rats were induced with stroke through photothrombotic occlusion of the middle cerebral artery and scanned serially between 1 h and day 3 after induction using DWI and PWI with a 1.5 T MR scanner. The relative lesion volumes (rLV) on MRI and triphenyl tetrazolium chloride-stained specimens were defined as the proportion of lesion volume over brain volume. Discrepancies in the rLV between PWI- and DWI-derived apparent diffusion coefficient (ADC) maps were expressed by subtraction of the ADC from PWI, resulting in three possible patterns: (i) (PWI-ADC > 10% of PWI) denoting a mismatch; (ii) (-(10% of PWI) <or= PWI-ADC <or= 10% of PWI) denoting a match; and (iii) (PWI-ADC < -(10% of PWI)) denoting a reverse mismatch. The differences were compared with the minuend being either early PWI (ePWI) or instant PWI (iPWI) and the subtrahend being instant ADC (iADC). The occurrence and evolution of PWI-ADC patterns were analysed. Over time, PWI-ADC discrepancies evolved from mismatch, through to match, to reversed mismatch. The PWI-ADC mismatch still existed 3 days after MCA occlusion in one to three of the eight cases. The rLVs and mismatch incidences between the ePWI-iADC and iPWI-iADC models were linear correlated. A higher mismatch rate occurred in iPWI-iADC within day 1 and in ePWI-iADC at day 3. Both ePWI and iPWI proved useful to define PWI-ADC patterns within day 1. At day 3, iPWI appeared more adequate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability of large diffusion/perfusion mismatch in anterior circulation strokes for 4 or more hours

BACKGROUND The stability of hypoperfused brain tissue in stroke patients with major artery occlusions is unknown. The purpose of this study was to determine the persistence of a diffusion/perfusion mismatch in patients with ICA or proximal MCA occlusions. METHODS Fourteen patients with ICA and/or proximal MCA occlusion and a diffusion/perfusion mismatch at presentation were studied. All were ...

متن کامل

Differences in the Evolution of the Ischaemic Penumbra in the Shrsp and Wky Rat

Background and Purpose: Stroke prone spontaneously hypertensive rats (SHRSP) are a highly pertinent stroke model with increased sensitivity to focal ischaemia compared to the normotensive reference strain (WKY). Study aims were to investigate temporal changes in the ischaemic penumbra in SHRSP compared with WKY. Methods: Permanent middle cerebral artery occlusion was induced with intraluminal f...

متن کامل

Granulocyte-colony stimulating factor delays PWI/DWI mismatch evolution and reduces final infarct volume in permanent-suture and embolic focal cerebral ischemia models in the rat.

BACKGROUND AND PURPOSE Granulocyte-colony stimulating factor (G-CSF) is used clinically to attenuate neutropenia after chemotherapy. G-CSF acts as a growth factor in the central nervous system, counteracts apoptosis, and is neuroprotective in rodent transient ischemia models. METHODS We assessed the effect of G-CSF on ischemic lesion evolution in a rat permanent-suture occlusion model with di...

متن کامل

Rapid assessment of perfusion-diffusion mismatch.

BACKGROUND AND PURPOSE For MR perfusion-diffusion (PWI-DWI) mismatch to become routine in thrombolysis patient selection, rapid and reliable assessment tools are required. We examined interrater variability in PWI/DWI volume measurements and developed a rapid assessment tool based on the Alberta Stroke Program Early CT Scores (ASPECTS) system. METHODS DWI and PWI were performed in 35 patients...

متن کامل

Reliability of assessing percentage of diffusion-perfusion mismatch.

BACKGROUND AND PURPOSE Emergent neurovascular imaging holds promise in identifying new and optimum target populations for thrombolysis in stroke. Recent research has focused on patients with diffusion-weighted MRI (DWI)-perfusion-weighted MRI (PWI) mismatch as a marker of tissue at risk of infarction and a means to select the most suitable candidates for thrombolysis. The present study sought t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 81 963  شماره 

صفحات  -

تاریخ انتشار 2008