Impact of exacerbations on respiratory system impedance measured by a forced oscillation technique in COPD: a prospective observational study
نویسندگان
چکیده
BACKGROUND Forced oscillation technique (FOT) has been reported to be useful in the evaluation and management of obstructive lung disease, including COPD. To date, no data are available concerning long-term changes in respiratory system impedance measured by FOT. Additionally, although exacerbations have been reported to be associated with excessive lung function decline in COPD, the impact of exacerbations on the results of FOT has not been demonstrated. The aim of this study was to investigate the longitudinal changes in respiratory system impedance and the influence of exacerbations thereon. METHODS Between March 2011 and March 2012, outpatients who attended Kobe City Medical Center West Hospital with a diagnosis of COPD were assessed for eligibility. Baseline patient characteristics (age, sex, body mass index, smoking history, current smoking status, COPD stage), lung function (post-bronchodilator forced expiratory volume in 1 second [FEV1]), blood tests (neutrophils and eosinophils), FOT, and COPD assessment test results were collected at enrollment. Lung function and FOT were examined every 6 months until March 2016. Annual changes in FEV1 and FOT parameters were obtained from the slope of the linear regression curve. The patients were divided into 2 groups based on exacerbation history. RESULTS Fifty-one of 58 patients with COPD were enrolled in this study. The median follow-up period was 57 (52-59) months. Twenty-five (49%) patients experienced exacerbations. A significant annual decline in FEV1 and respiratory system impedance were shown. Additionally, annual changes in FEV1, respiratory system resistance at 5 Hz, respiratory system reactance at 5 Hz, and resonant frequency were greater in patients with exacerbations than in those without exacerbations. CONCLUSION Exacerbations of COPD lead not only to a decline in lung function but also to an increase in respiratory system impedance.
منابع مشابه
Association between respiratory impedance measured by forced oscillation technique and exacerbations in patients with COPD
Background It is well known that increased airflow limitation as measured by spirometry is associated with the risk of exacerbation in patients with COPD. The forced oscillation technique (FOT) is a noninvasive method used to assess respiratory impedance (resistance and reactance) with minimal patient cooperation required. The clinical utility of the FOT in assessing the risk of exacerbations o...
متن کاملRespiratory impedance is correlated with morphological changes in the lungs on three-dimensional CT in patients with COPD
The forced oscillation technique provides information concerning respiratory impedance, which comprises resistance and reactance of the respiratory system. However, its relationship with morphological changes of the lungs in chronic obstructive pulmonary disease (COPD) remains unclear. Respiratory impedance and spirometric data were evaluated in 98 patients with COPD and 49 reference subjects. ...
متن کاملPerioperative evaluation of respiratory impedance using the forced oscillation technique: a prospective observational study
BACKGROUND Intravascular fluid shifts, mechanical ventilation and inhalational anesthetic drugs may contribute to intraoperative lung injury. This prospective observational study measured the changes in respiratory impedance resulting from inhalational anesthesia and mechanical ventilation in adults undergoing transurethral resection of bladder tumors. The components of respiratory impedance (r...
متن کاملFluctuations and determinism of respiratory impedance in asthma and chronic obstructive pulmonary disease.
Asthma and COPD are chronic respiratory diseases that fluctuate widely with regard to clinical symptoms and airway obstruction, complicating treatment and prediction of exacerbations. Time series of respiratory impedance obtained by the forced oscillation technique are a convenient tool to study the respiratory system with high temporal resolution. In previous studies it was suggested that powe...
متن کاملThe association of tidal EFL with exercise performance, exacerbations, and death in COPD
BACKGROUND Tidal expiratory flow limitation (EFLT) is frequently found in patients with COPD and can be detected by forced oscillations when within-breath reactance of a single-breath is ≥0.28 kPa·s·L-1. The present study explored the association of within-breath reactance measured over multiple breaths and EFLT with 6-minute walk distance (6MWD), exacerbations, and mortality. METHODS In 425 ...
متن کامل