Percutaneous recanalisation of chronically occluded coronary arteries with the CrossBoss/Stingray system: first experience (report of three cases).

نویسندگان

  • Jakub Drozd
  • Julian Strange
  • Agnieszka Wysokińska
  • Grzegorz Sobieszek
  • Michał Tomaszewski
چکیده

BACKGROUND AND AIM Percutaneous coronary interventions (PCI) within chronically occluded coronary arteries remain challenging procedures with a lower success rate compared to classic PCI. However, over the last years we have witnessed many technological advances in the treatment of chronic total occlusion (CTO) including new wires, retrograde approach, subintimal tracking and re-entry technique, all underlying which the current success rate of up to 95% in dedicated centres. Subintimal space wire penetration is no longer a problem that would require terminating the procedure. It is now a desired part of hybrid CTO approach involving both antegrade and retrograde crossing and re-entry. The new device which facilitates controlled dissection and true lumen re-entry is the Boston Scientific Coronary CTO Crossing System consisting of a CrossBoss micro-catheter and Stingray balloon and dedicated wire. METHODS On October 29th and 30th, 2014, percutaneous coronary recanalisation using the CrossBoss/Stingray system was performed in 3 men aged 63-75, with symptoms of stable CCS class II/III angina, without prior myocardial infarction in the area of CTO artery supply and with preserved myocardial contractility. Each patient underwent at least one previous unsuccesful antegrade/retrograde CTO recanalisation procedure. The J-CTO score was 3-4. RESULTS The procedure was successful in all 3 patients: 2 right coronary arteries and 1 left anterior descending artery were opened. In all 3 cases, both the CrossBoss catheter and the Stingray re-entry system were used. Two to three drug eluting stents were implanted in each patient, with the total length of 62-106 mm and final TIMI 3 flow. The mean procedure time was 141 min (130-150 min), mean fluoroscopy time was 53 min (48-56 min), absorbed dose was 4772 mGy (4098-5633 mGy), dose area product was 565,208 cGy × cm² (535,109-590,266 cGy × cm²), and the mean contrast volume was 343 mL (320-350 mL). No procedure-related complications were note except for an asymptomatic increase in high-sensitivity troponin T level up to 157 ng/mL (reference range 0-14 ng/mL) in 1 patient. CONCLUSIONS The Boston Scientific Coronary CTO Crossing System is a useful device for percutaneous recanalisation of chronically occluded coronary arteries. It helps to achieve procedural success in more complex cases within relatively short crossing times and with a limited amount of the contrast agent and X-ray dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous angioplasty of chronically occluded coronary arteries: long-term clinical follow-up.

BACKGROUND Percutaneous coronary intervention (PCI) of a chronic total occlusion (CTO) is one of the most demanding procedures in interventional cardiology. In spite of growing experience and technological progress, efficacy of PCI of CTO remains lower than that of standard PCI. AIM To evaluate long-term clinical results of PCI in patients with stable angina and CTO. METHODS The study invol...

متن کامل

New Advances in Chronic Total Occlusions.

Coronary chronic total occlusions (CTOs) still represent the greatest technical challenge that interventional cardiologists face. CTOs remain seriously undertreated with percutaneous techniques, far below their prevalence. One reason for the low uptake was the suboptimal CTO percutaneous coronary intervention (PCI) success rates over a long period of time. During the last years, dedicated group...

متن کامل

Use of the Stingray Re-Entry System in Two Complex Cases of Occluded Superficial Femoral Arteries

Totally occluded infrainguinal arterial disease presents formidable challenges to endovascular revascularization. A variety of devices have been made available to make the crossing of these lesions more amenable to endovascular techniques. We discuss the novel use of a device that has been developed for crossing occluded coronary arteries, the Stingray Re-Entry System.

متن کامل

Balloon recanalisation of a chronically occluded left internal mammary artery graft.

A patient in whom balloon recanalisation of a chronically occluded left internal mammary artery graft was successful is described. A Magnum-Magnarail system was used, and a four month follow up showed no restenosis.

متن کامل

Initial clinical experience of CrossBoss catheter for in-stent chronic total occlusion lesions

BACKGROUND The CrossBoss coronary chronic total occlusion (CTO) crossing catheter has been demonstrated to have greatly improved the success rate of crossing CTO lesions, but there are no published data on its application for in-stent CTO lesions. METHODS In the current study, we retrospectively reviewed the clinical data of 8 patients with in-stent CTO lesions that were managed with the Cros...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 73 9  شماره 

صفحات  -

تاریخ انتشار 2015