Ammonia emissions from a U.S. broiler house--comparison of concurrent measurements using three different technologies.

نویسندگان

  • Kenneth D Casey
  • Richard S Gates
  • Richard C Shores
  • Eben D Thoma
  • D Bruce Harris
چکیده

There is a need for robust and accurate techniques for the measurement of ammonia (NH3) and other atmospheric pollutant emissions from poultry production facilities. Reasonable estimates of NH3 emission rate (ER) from poultry facilities are needed to guide discussions about the industry's impact on local and regional air quality. The design of these facilities features numerous emission points and results in emission characteristics of relatively low concentrations and exhaust flow rates that vary diurnally, seasonally, and with bird age over a considerable range. These factors combine to render conventional emissions monitoring approaches difficult to apply. Access to these facilities is also often restricted for biosecurity reasons. The three objectives of this study were (1) to compare three methods for measuring exhaust NH3 concentrations and thus ERs, (2) to compare ventilation rates using in situ measured fan characteristics versus using manufacturer sourced fan curves, and (3) to examine limitations of the alternative measurement technologies. In this study, two open-path monitoring systems operating outside of the buildings were compared with a portable monitoring system sampling upstream of a primary exhaust fan. The position of the open-path systems relative to the exhaust fans, measurement strategy adopted, and weather conditions significantly influenced the quality of data collected when compared with the internally located, portable monitoring system. Calculation of exhaust airflow from the facility had a large effect on calculated emissions and assuming that the installed fans performed as per published performance characteristics potentially overestimated emissions by 13.6-26.8%. The open-path measurement systems showed promise for being able to obtain ER measurements with minimal access to the house, although the availability of individual fan characteristics markedly improved the calculated ER accuracy. However, substantial operator skill and experience and favorable weather conditions were required to obtain good quality results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Ammonia Emissions from Poultry Houses Based on Diurnal Integration vs. Daily Means of Gas Concentration and Building Ventilation Rate

Quantification of aerial emissions from animal feeding operations (AFOs) requires the knowledge of both concentration of the constituent of interest and the ventilation rate (VR) through the emitting source. Daily emissions can be and are normally determined from diurnal integration of frequent measurements, referred to as the diurnal integration method (DIM), but is resource intensive. Alterna...

متن کامل

Evaluation of Ammonia Emissions from Broiler Litter

Ammonia (NH3) emissions from poultry litter results in air pollution and can cause high levels of NH3 in poultry houses, which negatively impacts bird performance. The objectives of this study were to: (1) conduct a nitrogen (N) mass balance in broiler houses by measuring the N inputs (bedding, chicks, and feed) and N outputs (birds marketed, mortality, litter/cake, NH3 emissions, and nitrous o...

متن کامل

Vertical Stratification of Ammonia in a Broiler House

The broiler industry is not immune to the problematic nature of NH3 production in animal rearing facilities. Though the headlines of today focus on environmental impact considerations, the detrimental effects of the house air quality on farmers and birds remain considerable for industry viability. This research investigated the vertical stratification of in-house NH3 combined with sampling posi...

متن کامل

Broiler litter ammonia emissions near sidewalls, feeders, and waterers.

Ammonia (NH3) volatilized from broiler litter diminishes indoor air quality, which can potentially decrease bird productivity. Emissions of NH3 exhausted from broiler houses pose environmental concerns for ecosystem biodiversity, aquatic nutrient enrichment, and particulate formation in the atmosphere. Research was conducted sampling litter (rice hull base) in 3 tunnel-ventilated commercial bro...

متن کامل

Evaluation of a sprinkler cooling system on inhalable dust and ammonia concentrations in broiler chicken production.

Workers are exposed to dust in broiler chicken production during daily work activities. Poultry dust may contain inflammatory agents (e.g., endotoxin) and inhalation exposure has been associated with pulmonary symptoms. Current practice to reduce worker exposure to poultry dust is the use of respiratory protection (e.g., elastomeric face-piece respirator with a P100 and ammonia chemical cartrid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Air & Waste Management Association

دوره 60 8  شماره 

صفحات  -

تاریخ انتشار 2010