Validity and repeatability of inertial measurement units for measuring gait parameters.

نویسندگان

  • Edward P Washabaugh
  • Tarun Kalyanaraman
  • Peter G Adamczyk
  • Edward S Claflin
  • Chandramouli Krishnan
چکیده

Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Towards Mobile Gait Analysis: Concurrent Validity and Test-Retest Reliability of an Inertial Measurement System for the Assessment of Spatio-Temporal Gait Parameters

The purpose of this study was to assess the concurrent validity and test-retest reliability of a sensor-based gait analysis system. Eleven healthy subjects and four Parkinson's disease (PD) patients were asked to complete gait tasks whilst wearing two inertial measurement units at their feet. The extracted spatio-temporal parameters of 1166 strides were compared to those extracted from a refere...

متن کامل

Inertial Measurement System for Human Gait Analysis

An inertial measurement system is described in this study. In the first part of the paper history and gait cycle terminology are described and a relevant research is made. The system is used for an analysis of human gait and determination of its major parameters. Several inertial measurement units (IMUs) are attached to subject’s feet. The program is used to analyze original signals from the IM...

متن کامل

Gait Parameters Change Prior to Freezing in Parkinson's Disease: A Data-Driven Study with Wearable Inertial Units

Freezing of gait (FoG) is a motor impairment among patients with advanced Parkinson’s disease which is associated with falls and has a negative impact on a patient’s quality of life. Wearable systems have been developed to detect FoG and to help patients resume walking by means of rhythmical cueing. A step further is to predict the FoG and start cueing a few seconds before it happens, which mig...

متن کامل

A Real-time Motion Tracking Wireless System for Upper Limb Exosuit Based on Inertial Measurement Units and Flex Sensors (TECHNICAL NOTE)

This paper puts forward a real-time angular tracking (motion capture) system for a low cost upper limb exosuit based on sensor fusion; which is integrated by an elastic sleeve-mitten, two inertial measurement units (IMU), two flex sensors and a wireless communication system. The device can accurately detect the angular position of the shoulder (flexion-extension, abduction-adduction and interna...

متن کامل

Comparison of different methods for the estimation of gait temporal parameters using a single inertial sensor mounted on the lower trunk: application to elderly and hemiparetic subjects

The estimation of gait temporal parameters with wearable inertial measurement units (IMU) has been a research topic of interest in clinical gait analysis. Several methods, based on the use of a single IMU, have been proposed for their estimate, showing in most cases a sufficiently low number of missed and extra events and a satisfactory accuracy when applied to the gait of healthy subjects. In ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Gait & posture

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2017