Photoacoustic tomography with a single detector in a reverberant cavity.

نویسندگان

  • B T Cox
  • P C Beard
چکیده

In conventional biomedical photoacoustic tomography (PAT), ultrasonic pulses generated through the absorption of nanosecond pulses of near-infrared light are recorded over an array of detectors and used to recover an image of the initial acoustic pressure distribution within soft tissue. This image is related to the tissue optical coefficients and therefore carries information about the tissue physiology. For high resolution imaging, a large-area detector array with a high density of small, sensitive elements is required. Such arrays can be expensive, so reverberant-field PAT has been suggested as a means of obtaining PAT images using arrays with a smaller number of detectors. By recording the reflections from an acoustically reverberant cavity surrounding the sample, in addition to the primary acoustic pulse, sufficient information may be captured to allow an image to be reconstructed without the need for a large-area array. An initial study using two-dimensional simulations was performed to assess the feasibility of using a single detector for PAT. It is shown that reverberant-field data recorded at a single detector are sufficient to reconstruct the initial pressure distribution accurately, so long as the shape of the reverberant cavity makes it ray-chaotic. The practicalities of such an approach to photoacoustic imaging are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoacoustic tomography with a limited-aperture planar sensor and a reverberant cavity

Biomedical photoacoustic tomography (PAT) is a soft-tissue imaging modality which combines the high spatial resolution of ultrasound (US) with the contrast and spectroscopic opportunities afforded by imaging optical absorption. Planar US arrays composed of piezoelectric or optical detector elements with small element sizes and fast acquisition times are readily available, making them an attract...

متن کامل

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...

متن کامل

Performance characterization of low-cost, high-speed, portable pulsed laser diode photoacoustic tomography (PLD-PAT) system.

Photoacoustic tomography systems that uses Q-switched Nd:YAG/OPO pulsed lasers are expensive, bulky, and hence limits its use in clinical applications. The low pulse repetition rate of these lasers makes it unsuitable for real-time imaging when used with single-element ultrasound detector. In this work, we present a pulsed laser diode photoacoustic tomography (PLD-PAT) system that integrates a ...

متن کامل

Characteristics of optimized fibre-optic ultrasound receivers for minimally invasive photoacoustic detection

A range of miniature (125μm o.d.) fibre optic ultrasound sensors based on the use of interferometric polymer optical cavities has been developed for minimally invasive photoacoustic imaging and sensing applications. It was observed that by careful selection of both the fibre tip and cavity geometry it is possible to achieve exceptional acoustic performance. Specifically, rounding the tip of the...

متن کامل

An All-Fiber-Optic Combined System of Noncontact Photoacoustic Tomography and Optical Coherence Tomography

We propose an all-fiber-based dual-modal imaging system that combines noncontact photoacoustic tomography (PAT) and optical coherence tomography (OCT). The PAT remotely measures photoacoustic (PA) signals with a 1550-nm laser on the surface of a sample by utilizing a fiber interferometer as an ultrasound detector. The fiber-based OCT, employing a swept-source laser centered at 1310 nm, shares t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 125 3  شماره 

صفحات  -

تاریخ انتشار 2009