The effect of lateral wall perforation on screw pull-out strength: a cadaveric study

نویسندگان

  • Nan Li
  • Da He
  • Yonggang Xing
  • Yanwei LV
  • Wei Tian
چکیده

BACKGROUND Lateral pedicle wall perforations occur frequently during pedicle screw insertion. Although it is known that such an occurrence decreases the screw pull-out strength, the effect has not been quantified biomechanically. MATERIALS AND METHODS Twenty fresh cadaveric lumbar vertebrae were harvested, and the bone mineral density (BMD) of each was evaluated with dual-energy radiography absorptiometry (DEXA). Twenty matched, 6.5-mm pedicle screws were inserted in two different manners in two groups, the control group and the experimental group. In the control group, the pedicle screw was inserted in a standard fashion taking adequate precaution to ensure there was no perforation of the wall. In the experimental group, the pedicle screw was inserted such that its trajectory perforated the lateral wall. Group assignments were done randomly, and the maximal fixation strength was recorded for each screw pull-out test with a material-testing system (MTS 858 II). RESULTS The average BMD for both groups was 0.850 g/cm(2) (0.788-0.912 g/cm(2)). The average (and standard deviation) maximal pull-out forces were 1,015.8 ± 249.40 N for the experimental group and 1,326.0 ± 320.50 N for the control group. According to a paired t-test, the difference between the two groups was statistically significant (P < 0.001). CONCLUSION The results of this study confirm that the maximal pull-out strength of pedicle screws decreases by approximately 23.4% when the lateral wall is perforated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Comparative Analysis of Effect of Density, Insertion Angle and Reinsertion on Pull-Out Strength of Single and Two Pedicle Screw Constructs Using Synthetic Bone Model

STUDY DESIGN Biomechanical study. PURPOSE To determine the effect of density, insertion angle and reinsertion on pull-out strength of pedicle screw in single and two screw-rod configurations. OVERVIEW OF LITERATURE Pedicle screw pull-out studies have involved single screw construct, whereas two screws and rod constructs are always used in spine fusions. Extrapolation of results using the si...

متن کامل

Triangulated pedicle screw construct technique and pull-out strength of conical and cylindrical screws.

To compare the mechanical effectiveness of a new conical screw design with a conventional cylindrical screw design, the screw insertion time, torque, and pull-out strength of single-pedicle screw and triangulated-pedicle screw constructs of each type of screw were compared in human cadaveric vertebral bodies. The time required to insert the conical screws was less than that required for cylindr...

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

The role of the dorsal vertebral cortex in the stability of transpedicular screws. A biomechanical study in human cadaveric vertebrae.

The aim of this biomechanical study was to investigate the role of the dorsal vertebral cortex in transpedicular screw fixation. Moss transpedicular screws were introduced into both pedicles of each vertebra in 25 human cadaver vertebrae. The dorsal vertebral cortex and subcortical bone corresponding to the entrance site of the screw were removed on one side and preserved on the other. Biomecha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015