An implantable synthetic SPECT lesion: a bridge from phantom to reality.

نویسندگان

  • M Bret Abbott
  • Lars R Furenlid
  • Don W Wilson
  • Gail D Stevenson
  • James M Woolfenden
  • Harrison H Barrett
چکیده

UNLABELLED Small-animal imaging systems are often characterized using phantoms, which may not predict performance in clinical applications. An implantable synthetic SPECT lesion would facilitate characterization of lesion detectability in a living animal. METHODS Anion-exchange columns with bed volumes of 100-300 nL were constructed from medical-grade polyvinyl chloride tubing and resin. The columns were tested in an excised mouse femur and implanted in the femur of a living mouse. Imaging was performed using a prototype dual-modality SPECT/CT system. RESULTS Activity of 7.4-22.2 MBq (0.2-0.6 mCi) localized within the synthetic lesion. The synthetic lesions were reused multiple times. Mice tolerated the implanted columns without complications for up to 8 wk. CONCLUSION A reusable, synthetic SPECT lesion was constructed and implanted in the femur of a living mouse. The synthetic lesion is useful for the development of imaging schemes and for more realistically evaluating imaging-system performance in the context of a living animal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Collimator-detector response compensation in molecular SPECT reconstruction using STIR framework

Introduction:It is well-recognized that collimator-detector response (CDR) is the main image blurring factor in SPECT.  In this research, we compensated the images for CDR in molecular SPECT by using STIR reconstruction framework. Methods: To assess resolution recovery capability of the STIR, a phantom containing five point sources along with a micro Derenzo p...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Simulation of a Quality Control Jaszczak Phantom with SIMIND Monte Carlo and Adding the Phantom as an Accessory to the Program

Introduction Quality control is an important phenomenon in nuclear medicine imaging. A Jaszczak SPECT Phantom provides consistent performance information for any SPECT or PET system. This article describes the simulation of a Jaszczak phantom and creating an executable phantom file for comparing assessment of SPECT cameras using SIMIND Monte Carlo simulation program which is well-established fo...

متن کامل

Optimization of a SPECT system for imaging of 90Y in liver using Monte Carlo method

Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affect...

متن کامل

Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 48 11  شماره 

صفحات  -

تاریخ انتشار 2007