Cancellation of the collisional frequency shift in caesium fountain clocks.
نویسندگان
چکیده
We have observed that the collisional frequency shift in primary caesium fountain clocks varies with the clock state population composition and, in particular, is zero for a given fraction of the |F=4,mF=0) atoms, depending on the initial cloud parameters. We present a theoretical model explaining our observations. The possibility of the collisional shift cancellation implies an improvement in the performance of caesium fountain standards and a simplification in their operation.
منابع مشابه
NPL Cs fountain frequency standards and the quest for the ultimate accuracy
NPL operates a system of two primary caesium fountain clocks consisting of a fully characterised standard NPL-CsF2 together with a new standard NPL-CsF3, which has recently become operational. Both fountains feature a single-stage vapour-loaded magneto-optical trap as the source of cold atoms and an approximate cancellation of the potentially large cold collision frequency shift. As a result, t...
متن کاملCollisional frequency shifts in 133Cs fountain clocks.
We present a theoretical analysis of the density dependent frequency shift in Cs fountain clocks using the highly constrained binary collision model described by Leo et al. [Phys. Rev. Lett. 85, 2721 (2000)]. We predict a reversal in the clock shift at temperatures near 0.08 microK. Our results show that s waves dominate the collision process. However, as a consequence of the large scattering l...
متن کاملEvaluation of long term performance of continuously running atomic fountains
An ensemble of rubidium atomic fountain clocks has been put into operation at the US Naval Observatory (USNO). These fountains are used as continuous clocks in the manner of commercial caesium beams and hydrogen masers for the purpose of improved timing applications. Four fountains have been in operation for more than two years and are included in the ensemble used to generate the USNO master c...
متن کاملCesium Atomic Fountain Clocks at Nmij
We describe the recent progress in our cesium atomic fountains at National Metrology Institute of Japan (NMIJ). We have developed three atomic fountains: NMIJ-F1, NMIJ-F2, and a truncated atomic beam fountain. NMIJ-F1 has been the primary frequency standard with uncertainty of 4×10 -15 since 2004. Especially in the last 4 years, we have reported the data to Bureau International des Poids et Mes...
متن کاملCold collision frequency shifts in a 87Rb atomic fountain.
We present measurements of cavity frequency pulling and collisional frequency shifts in a 87Rb fountain with a frequency resolution of 3x10(-16). Agreement with theory is found for the cavity pulling and the measured collisional shifts. The clock shift is found at least 50 times smaller than in 133Cs.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical review letters
دوره 98 15 شماره
صفحات -
تاریخ انتشار 2007