Radon exposures in a Jerusalem public school.
نویسندگان
چکیده
In December 1995, ambient radon levels exceeding 10,000 Bq/m3 were measured in a basement shelter workroom of a multilevel East Talpiot, Jerusalem, public elementary school (six grades, 600 students). The measurements were taken after cancers (breast and multiple myeloma) were diagnosed in two workers who spent their workdays in basement rooms. The school was located on a hill that geologic maps show to be rich in phosphate deposits, which are a recognized source for radon gas and its daughter products. Levels exceeding 1000,000 Bq/m3 were measured at the mouth of a pipe in the basement shelter workroom, the major point of radon entry. The school was closed and charcoal and electret ion chamber detectors were used to carry out repeated 5-day measurements in all rooms in the multilevel building over a period of several months. Radon concentrations were generally higher in rooms in the four levels of the building that were below ground level. There were some ground-level rooms in the building in which levels reached up to 1300 Bq/m3. In rooms above ground level, however, peak levels did not exceed 300 Bq/m3. Exposure control based on sealing and positive pressure ventilation was inadequate. These findings suggested that radon diffused from highly contaminated basement and ground-floor rooms to other areas of the building and that sealing off the source may have led to reaccumulation of radon beneath the building. Later, subslab venting of below-ground radon pockets to the outside air was followed by more sustained reductions in indoor radon levels to levels below 75 Bq/m3. Even so, radon accumulated in certain rooms when the building was closed. This sentinel episode called attention to the need for a national radon policy requiring threshold exposure levels for response and control. A uniform nationwide standard for school buildings below 75 Bq/m3 level was suggested after considering prudent avoidance, the controversies over risk assessment of prolonged low-level exposures in children, and the fact that exposures in most locations in the Talpiot school could be reduced below this level. Proposal of this stringent standard stimulated the search for a strategy of risk control and management based on control at the source. This strategy was more effective and probably more cost effective than one based on suppression of exposure based on sealing and ventilation. Because many Israeli areas and much of the West Bank area of the Palestinian National Authority sit on the same phosphate deposits, regional joint projects for surveillance and control may be indicated.
منابع مشابه
Public exposure to natural radiation sources (Ramsar Case Study)
Introduction: Human beings are naturally exposed to ionizing radiation in any environment. There are two main contributors to radiation exposures from natural sources: cosmic rays, Cosmo genic radionuclides, and radioactive nuclides that originated in the earth's crust. According to the latest data provided by the United Nations Scientific Committee on the Effects of Atomic Rad...
متن کاملAssessment of Effective Dose Equivalent from Internal Exposure to 222Rn in Ramsar City
Introduction In this study, effective dose equivalent for the public due to internal exposure to 222radon (222Rn) was evaluated in three regions of Ramsar, a northern coastal city in Iran. Materials and Methods Measurements were carried out using a radon monitoring device. Outdoor and indoor radon concentrations were measured within 24 hours with an integration in...
متن کاملIndoor exposure assessment of radon in the elementary schools, Palestine
Background: Many public health agencies rank residential radon exposure as the second leading cause of lung cancer after cigarette smoking. It has been shown that the risk coefficient for lung cancer is higher for children than that for adults. Therefore, indoor radon measurements were carried out in the elementary schools of Tulkarem province, West Bank, Palestine. Materials and Methods: Two h...
متن کاملRisk Perception and Driving Forces For
The motivation for performing indoor radon reduction measurements or mitigation are generally communicated by the commercial radon industry on the basis of identifying and eliminating a potential health hazard. The role of the commercial indoor radon industry is complicated by the different perspectives of the problem that have developed for various interested parties. Interested parties includ...
متن کاملAssociation of School District Policies for Radon Testing and Radon-Resistant New Construction Practices with Indoor Radon Zones
Radon is a naturally occurring, colorless, odorless, and tasteless radioactive gas. Without testing, its presence is unknown. Using nationally representative data from the 2012 School Health Policies and Practices Study, we examined whether the prevalence of school district policies for radon testing and for radon-resistant new construction practices varied by district location in relation to t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental Health Perspectives
دوره 105 شماره
صفحات -
تاریخ انتشار 1997