SCIENTIFIC CORRESPONDENCE A new technique for tear film fluorophotometry

نویسندگان

  • N Eter
  • M Göbbels
چکیده

Aim: To develop a reliable and objective non-touch technique for determination of tear volume and tear secretion by means of tear film fluorophotometry. Methods: 10 defined concentrations of sodium fluorescein were given in an artificial chamber and measured by the Fluorotron Master (Coherent Radiation Inc). A calibration line was established and the calibration equation was programmed into the Fluorotron Master computer software. In 28 patients (56 eyes) with dry eye symptoms and 15 volunteers (30 eyes) tear volume and tear secretion were then measured directly without taking a tear sample, using the new technique. Results: The values obtained by the Fluorotron Master measuring 10 defined fluorescein concentrations within an artificial chamber are approximately 100 times lower than the actual concentrations. The calibration line led to a calibration equation: y = 36 + 0.01 × X. The mean tear secretion in 56 eyes of patients with dry eye symptoms was 2.48 μl/min, compared to 3.4 μl/min in healthy volunteers. The difference was statistically significant. Average tear volume was 7.0 μl in patients and 7.2 μl in healthy volunteers with no statistically significant difference. Conclusion: The method developed is a simple and reliable non-touch technique without the need for taking a tear sample, which makes the examination faster and more comfortable for the patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new technique for tear film fluorophotometry.

AIM To develop a reliable and objective non-touch technique for determination of tear volume and tear secretion by means of tear film fluorophotometry. METHODS 10 defined concentrations of sodium fluorescein were given in an artificial chamber and measured by the Fluorotron Master (Coherent Radiation Inc). A calibration line was established and the calibration equation was programmed into the...

متن کامل

Assessment of tear film dynamics: quantification approach.

The dynamics of the tear film are reviewed with specific reference to the biophysical aspects: distribution, turnover and elimination through evaporation, drainage, and absorption. The review concentrates on quantitative assessments and is confined to aspects of the dynamics that can be fully and directly measured. The techniques of fluorophotometry, fluorescein clearance, lacrimal scintigraphy...

متن کامل

Tear secretion and tear film function in insulin dependent diabetics.

BACKGROUND Diabetic patients often complain of dry eye symptoms, such as burning and/or foreign body sensation. The aim of the present study was to investigate whether diabetes mellitus is correlated with tear film dysfunction and/or tear hyposecretion. METHODS In 86 consecutive insulin dependent diabetics with retinopathy and 84 non-diabetic controls (age and sex matched) we performed fluoro...

متن کامل

Turnover rate of tear-film lipid layer determined by fluorophotometry

AIM This study was performed to independently assess the turnover rates of aqueous and lipid layers of the tear film. METHODS Two fluorescent dyes, fluorescein sodium and 5-dodecanoylaminofluorescein (DAF), which is a free-fatty-acid conjugate of fluorescein, were applied to the right eye of 12 healthy volunteers. Fluorescent intensity of the precorneal tear film was measured at the central c...

متن کامل

Basal tear turnover and topical timolol in glaucoma patients and healthy controls by fluorophotometry.

To assess the effect of glaucoma and timolol on tear secretion, basal tear turnover was measured with fluorophotometry in 13 open-angle glaucoma patients not using any ophthalmic medication, 24 patients using timolol medication daily, and 41 healthy control subjects. Basal tear turnover is defined as the tear turnover at the lowest level of reflex lacrimation possible under physiologic conditio...