SU-E-T-549: On Importance of Accurate Treatment Couch Modeling in SmartArc VMAT Plans.
نویسندگان
چکیده
PURPOSE We investigate the impact of a treatment couch and its modeling in a treatment planning system on accurate dose delivery in Volumetric Modulated Arc Therapy (VMAT). METHODS A cone-beam CT of a Varian couch on a Varian Clinac 21EX unit, consisting of a carbon-fiber imaging couch top and supporting rails, was acquired, and a couch model was created in Philips Pinnacle 9.0 TPS based on the geometry of the couch top and the rails. The densities of the modeled couch top and the rails were based on the Hounsfield Unit and CT number-to-density information obtained from the CBCT scan. The densities were then adjusted based on the ion chamber measurements of a beam transmitting through the couch posteriorly at different gantry angles varying 1-5 degrees. SmartArc VMAT plans for patient treatment with and without the modeled couch were then generated and dose distributions were verified using the IBA MatriXX 2D ion chamber array. RESULTS We found that depending on the gantry angle the beam can be attenuated by up to 17% when going through the supporting rails, and up to 5% when passing through the couch top. Because of this, dose distributions of SmartArc plans were not accurate and did not pass the dose verification criteria without accurate modeling of the treatment couch. Adding the couch model remedies this problem and avoids underdosing the target. CONCLUSIONS We showed that the impact of a treatment couch in radiation therapy can be significant, and it is essential to include an accurate model of the couch in the treatment planning system, particularly for SmartArc VMAT plans in Philips Pinnacle TPS.
منابع مشابه
Quantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)
Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...
متن کاملSU-E-T-592: Comparison of Low Dose Volume and Integral Dose in Rotational Arc Radiation Therapy Modalities.
PURPOSE To compare low dose volume and integral dose of various rotational arc radiation therapy modalities, including helical tomotherapy (HT) and other volumetric modulated arc therapies (VMAT). METHODS A digital cylindrical phantom and an anthropomorphic pelvic phantom were used in the study. HT treatment was planned on TomoTherapy Planning Station (Accuray) and VMAT plans were generated o...
متن کاملSU-E-T-584: Dosimetric Comparison Between Static IMRT and VMAT for a Four- Lesion Brain Treatment.
PURPOSE Sparing brain volume is the goal when designing plans for multiple brain tumors. We compared dose distributions for tumor and normal tissues using VAMT and static IMRT. METHODS A patient presented with recurrent meningioma with 4 lesions identified. The greatest dimensions for the tumors were 0.4 to 2.0 cm. The tumor sizes and locations can be treated with a single plan with 1.8 Gy/fr...
متن کاملDosimetric Comparison of Craniospinal Axis Irradiation (CSI) Treatments Using Helical Tomotherapy, SmartarcTM, and 3D Conventional Radiation Therapy
Purpose: Craniospinal axis irradiation (CSI) is a method of treating various central nervous system malignancies. The large target volume typically includes entire spinal cord and whole brain. Dosimetric comparison was performed between tomotherapy, volumetric modulated arc therapy (VMAT), and 3D conformal radiation therapy (3D-CRT) for CSI. Methods and Materials: Five (n = 5) CSI patients were...
متن کاملComparative analysis of SmartArc‐based dual arc volumetric‐modulated arc radiotherapy (VMAT) versus intensity‐modulated radiotherapy (IMRT) for nasopharyngeal carcinoma
The purpose of this study was to evaluate and quantify the planning performance of SmartArc-based volumetric-modulated arc radiotherapy (VMAT) versus fixed-beam intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) using a sequential mode treatment plan. The plan quality and performance of dual arc-VMAT (DA-VMAT) using the Pinnacle3 Smart-Arc system (clinical version 9.0; P...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part18 شماره
صفحات -
تاریخ انتشار 2012