A hydrogen ion-selective poly(aniline) solid contact electrode based on dibenzylpyrenemethylamine ionophore for highly acidic solutions.
نویسندگان
چکیده
Hydrogen-ion selective solid contact electrodes based on tribenzylamine, dibenzylnaphthalenemethylamine, and dibenzylpyrenemethylamine ionophores were prepared. With these electrodes, we showed that the response ranges were influenced by the number of phenyl rings in the ionophores. The lower limits for a linear pH response in acidic solutions were pH 2.50, 0.65, and 0.50, respectively. As the number of phenyl rings in the ionophores increased, the slopes of the EMF responses of these electrodes did not change significantly, but their response extended toward an acidic range (shifted to pH 0.50). Thus, their dynamic response range became wider. A solid contact electrode with dibenzylpyrenemethylamine ionophore, in particular, showed the best selectivity, from the interference of cations and anions, and the best reproducibility of the EMF. This electrode was stored in Tris buffer solutions, artificial serum, and hydrofluoric acid solutions for one month without any loss of performance. Their response time was 8 s. Satisfactory results were obtained when it was tested directly with artificial serum (in pH range 6.0 - 8.5) and hydrofluoric acid.
منابع مشابه
Thiocyanate Ion Selective Solid Contact Electrode Based on Mn Complex of N,N'-BIs-(4-Phenylazosalicylidene)-O-Phenylene Diamine Ionophore
A thiocyanate ion selective poly(aniline) solid contact electrode based on manganese complex of N,N’-bis-(4-phenylazosalicylidene)-o-phenylene diamine ionophore was successfully developed. The electrode exhibits a good linear response of 58.1 mV/decade (at 20 ̊C ± 0.2 ̊C, r = 0.998) with in the concentration range of 1 × 10 ~ 1 × 10 M thiocyanate solution. The composition of this electrode was: i...
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملChromium (III) ion selective electrode based on di(benzylamino)glyoxime
A new poly(vinylchloride) membrane sensor for Cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. The electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with aNernstian slope of 20.3 ± 0.5 mV per decade and a detection limit of 2×10-7. It has a fast responsetime of
متن کاملHighly selective and sensitive sensor based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane as a heterocyclic ionophore
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two mont...
متن کاملSn (II) Ion- Selective Membrane Electrode based on Dibenzo-18-Crown-6
We found that dibenzo-18-crown-6 (DB18C6) can be used as an ionophore to make a tin (II)-ionselectivemembrane electrode. The electrode exhibits a near Nernstian response for Sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27.5 ± 0.6 mV per concentration decadein an acidic solution (pH=1). The limit of detection was 8.0× 10-7 M. It has a response time of < 20s an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 20 10 شماره
صفحات -
تاریخ انتشار 2004