Chronic Inflammation in an Anophthalmic Socket due to a Room Temperature Vulcanized Silicone Implant
نویسندگان
چکیده
Two case reports are used to illustrate the signs and symptoms, complications and treatments of chronic socket inflammation due to intraorbital implants. The ophthalmic examination, surgeries and treatments are documented. Two anophthalmic cases that underwent enucleation and multiple orbital surgeries to enhance the anophthalmic socket volume developed pain, intense discharge and contracted cavities with chronic inflammation in the socket which was nonresponsive to medical therapy. Computed tomography indicated a hypodense foreign body in both cases causing an intense inflammatory reaction. The implants were removed by excisional surgery and a room temperature vulcanized silicone implant was retrieved in both cases. Socket inflammation resolved in both cases after implant removal. An intraorbital inflammatory reaction against an intraorbital implant can cause chronic socket inflammation in patients with a history of multiple surgeries. Diagnosis requires imaging and the definitive treatment is implant removal.
منابع مشابه
Chronic Orbital Inflammation Associated to Hydroxyapatite Implants in Anophthalmic Sockets
Purpose We report 6 patients who received a hydroxyapatite (HA) orbital implant in the socket and developed chronic orbital inflammation unresponsive to conventional medical therapy. Case Reports We assisted 6 cases (4 males, 2 females) who received an HA orbital implant in the socket between 2015 and 2016 at King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia, and developed chronic orb...
متن کاملNatural Contamination and Surface Flashover on Silicone Rubber Surface under Haze–Fog Environment
Anti-pollution flashover of insulator is important for power systems. In recent years, haze-fog weather occurs frequently, which makes discharge occurs easily on the insulator surface and accelerates insulation aging of insulator. In order to study the influence of haze-fog on the surface discharge of room temperature vulcanized silicone rubber, an artificial haze-fog lab was established. Based...
متن کاملUse of Proplast II as a subperiosteal implant for the correction of anophthalmic enophthalmos.
BACKGROUND A variety of autogenous and alloplastic materials have been used as subperiosteal implants to correct anophthalmic enophthalmos. Proplast II is a synthetic porous composite of Teflon polymer and alumina. Proplast II offers a number of advantages over other commonly used alloplastic materials such as silicone and polymethyl methacrylate. It is light, porous, resilient, malleable, and ...
متن کاملAnophthalmic socket: choice of orbital implants for reconstruction.
This literature review considers the treatment of an anophthalmic socket and the controversial aspects of the implants used to restore the lost volume after enucleation or evisceration, including the different materials employed and the main problems encountered during anophthalmic socket reconstruction. Since the 1980s, when integrated implants were proposed, there has been much controversy ab...
متن کاملEffect of vulcanization temperature and dental stone colour on colour degradation of maxillofacial silicone elastomers
BACKGROUND Colour degradation is a major problem in maxillofacial silicone elastomers. Recent studies have focused on colour stability and the mechanical properties of the silicone elastomers. A colour match is also essential for the acceptance of the prosthesis by the patient. The aim of this study is to assess the colour degradation of the silicone elastomer after being moulded in different c...
متن کامل