Prediction of extubation outcome: a randomised, controlled trial with automatic tube compensation vs. pressure support ventilation
نویسندگان
چکیده
INTRODUCTION Tolerance of a spontaneous breathing trial is an evidence-based strategy to predict successful weaning from mechanical ventilation. Some patients may not tolerate the trial because of the respiratory load imposed by the endotracheal tube, so varying levels of respiratory support are widely used during the trial. Automatic tube compensation (ATC), specifically developed to overcome the imposed work of breathing because of artificial airways, appears ideally suited for the weaning process. We further evaluated the use of ATC in this setting. METHODS In a prospective study, patients who had received mechanical ventilation for more than 24 hours and met defined criteria for a weaning trial, underwent a one-hour spontaneous breathing trial with either ATC (n = 87) or pressure support ventilation (PSV; n = 93). Those tolerating the trial were immediately extubated. The primary outcome measure was the ability to maintain spontaneous, unassisted breathing for more than 48 hours after extubation. In addition, we measured the frequency/tidal volume ratio (f/VT) both with (ATC-assisted) and without ATC (unassisted-f/VT) at the start of the breathing trial as a pretrial predictor of extubation outcome. RESULTS There were no significant differences in any of the baseline characteristics between the two groups apart from a significantly higher Acute Physiology and Chronic Health Evaluation (APACHE) II score in the ATC group (p = 0.009). In the PSV group, 13 of 93 (14%) patients failed the breathing trial compared with only 6 of 87 (6%) in the ATC group; this observed 8% difference, however, did not reach statistical significance (p = 0.12). The rate of reintubation was not different between the groups (total group = 17.3%; ATC = 18.4% vs. PSV = 12.9%, p = 0.43). The percentage of patients who remained extubated for more than 48 hours was similar in both groups (ATC = 74.7% vs. PSV = 73.1%; p = 0.81). This represented a positive predictive value for PSV of 0.85 and ATC of 0.80 (p = 0.87). Finally, the ATC-assisted f/VT was found to have a significant contribution in predicting successful liberation and extubation compared with the non-significant contribution of the unassisted f/VT (unassisted f/VT, p = 0.19; ATC-assisted f/VT, p = 0.005). CONCLUSIONS This study confirms the usefulness of ATC during the weaning process, being at least as effective as PSV in predicting successful extubation outcome and significantly improving the predictive value of the f/VT. TRIAL REGISTRATION Current Controlled Trials ISRCTN16080446.
منابع مشابه
Automatic Tube Compensation versus Pressure Support Ventilation and Extubation Outcome in Children: A Randomized Controlled Study
Background. Automatic tube compensation (ATC) has been developed to overcome the imposed work of breathing due to artificial airways during spontaneous breathing trials (SBTs). Objectives. This study aimed to assess extubation outcome after an SBT (spontaneous breathing trial) with ATC compared with pressure support ventilation (PSV) and to determine the risk factors for extubation failure. Met...
متن کاملEarly Nasal Intermittent Positive Pressure Ventilation (NIPPV) versus Nasal Continuous Positive Airway Pressure (NCPAP) for Respiratory Distress Syndrome (RDS) in Infants of 28-36 weeks gestational age: a Randomized Controlled Trial
Background: Early nasal continuous positive airway pressure (NCPAP) has emerged as a primary modality of respiratory support for preterm infants withrespiratory distress syndrome (RDS). However, 30%-40% of these newborns need subsequent mechanical ventilation. Nasal intermittent positive pressure ventilation (NIPPV) is a promising alternative to NCPAP, especially in po...
متن کاملComparison between automatic tube compensation and continuous positive airway pressure during spontaneous breathing trials.
BACKGROUND Various methods to perform spontaneous breathing trials (SBTs) exist, but no one method has been shown to be superior. Automatic tube compensation (ATC) is a new and potentially advantageous ventilation mode to use during SBT. We compared ATC to continuous positive airway pressure (CPAP) during SBTs, to determine their efficacy in identifying patients ready to be liberated from mecha...
متن کاملThe Comparison of Automatic Tube Compensation (ATC) and T-piece During Weaning.
OBJECTIVE Automatic Tube Compensation (ATC) is a newly developed mechanical ventilatory support method. The aim of this study was to compare the ATC and the T-piece as a weaning method. METHODS Patients who were treated in ICU with mechanical ventilation for longer than 24 hours were included in this prospective clinical study. Fifty patients were divided into two groups for weaning, ATC or T...
متن کاملAutomatic tube compensation-assisted respiratory rate to tidal volume ratio improves the prediction of weaning outcome.
OBJECTIVE To assess whether the respiratory rate to tidal volume ratio (RVR) measured while receiving automatic tube compensation (ATC) [RVRATC] would have a better predictive value as a weaning measure than unassisted RVR. DESIGN Prospective cohort study. SETTING General ICU of a tertiary-care university hospital. PATIENTS Forty-three patients who received mechanical ventilation for > 24...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Critical Care
دوره 13 شماره
صفحات -