Time course of inhaled anaesthetic drug delivery using a new multifunctional closed-circuit anaesthesia ventilator. In vitro comparison with a classical anaesthesia machine.
نویسندگان
چکیده
BACKGROUND The aim of this study was to detail the time-course, defined as the changes in end-tidal drug concentration with time, and consumption of inhaled anaesthetics when using a multifunctional closed-circuit anaesthesia machine in various drug delivery modes, and to compare it with a classical anaesthesia machine using an out-of-circle vaporizer under high and low fresh gas flow conditions. METHODS Using an artificial test lung, sevoflurane and desflurane time-course and consumption were compared when using the Zeus apparatus (Dräger, Lubeck, Germany) with direct injection of inhaled anaesthetics or the Primus apparatus (Dräger, Lubeck, Germany) using a classical out-of-circle vaporizer. Anaesthetics were targeted at 1 and 2 MAC end-tidal during 15 min. For both apparatus, out-of-circle high and low fresh gas control (FGC) and for Zeus, auto-control (AC) modes (fixed fresh gas flow at 6 and 1 litre min(-1) and uptake mode) were compared. Time to reach target, initial overshoot and stability at target, and wash-out times were compared. RESULTS In FGC, an initial overshoot in end-tidal drug concentration is seen when using 6 litre min(-1) fresh gas flow and a slower time course is observed when using only 1 litre min(-1) in both apparatus. In auto-control mode, the time course of both sevoflurane and desflurane was very fast and not influenced by the changes in fresh gas flow. No overshoot at target was seen. At all settings, the wash-out times were faster when using Zeus than Primus. Inhaled anaesthetic consumption was lowest with the Zeus ventilator in uptake AC mode. CONCLUSION A combination of the fastest time course and lowest consumption of sevoflurane and desflurane was found when using the Zeus apparatus in AC uptake mode.
منابع مشابه
A new and versatile closed circuit anaesthetic machine with automatic and manual ventilation.
A versatile new anaesthetic machine embodying a ventilator with automatic and manual closed circuits, and with provision for semi-open circuits is described. The ventilator follows the principle of volume and time cycling and generally requires only a low flow of fresh gases (about 2 l./min). It is based on the original Smith-Clarke intermittent positive/ negative pressure respirator and is bot...
متن کاملModel-based administration of inhalation anaesthesia. 1. Developing a system model.
This paper is the first of a series of reports on a system model for the administration of inhalation anaesthesia. We present the development and basic testing of the model. It is a multiple-gas model; it covers fresh-gas flow rates from basal to more than total ventilation and includes an actual, not an idealized, circle-absorber breathing system featuring a standing bellows ventilator. Kineti...
متن کاملComparative evaluation of clinical efficiency of intramuscular diazepam-ketamine, medetomidine-ketamine, and xylazine-ketamine anaesthesia in Ring-necked pheasants (Phasianus colchicus)
Background: Several injectable anaesthetics and sedatives are used in various avian species for general anaesthesia. Birds are very sensitive animals and any mismanagement in a crisis can lead to immediate shock and death. Therefore, careful selection of the safest possible anaesthetic agent and dose is very important. Aims: The aim of this study was to examine...
متن کاملEvaluation of several drug combinations for intraperitoneal anaesthesia in adult male rats
The objective of this study was to evaluate several drug combinations for intraperitoneal anaesthesia in laboratory rats. Following dose determination of anaesthetics in a pilot study, 45 healthy adult male rats were randomly assigned in 9 treatment groups and received propofol (alone or in combination with xylazine, midazolam, or ketamine) or ketamine (in combination with xylazine, midazolam, ...
متن کاملXenon consumption during general surgery: a retrospective observational study
BACKGROUND High costs still limits the widespread use of xenon in the clinical practice. Therefore, we evaluated xenon consumption of different delivery modes during general surgery. METHODS A total of 48 patients that underwent general surgery with balanced xenon anaesthesia were retrospectively analysed according to the mode of xenon delivery during maintenance phase (ECO mode, AUTO mode or...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 94 3 شماره
صفحات -
تاریخ انتشار 2005