Stress degradation studies and development of a validated stability-indicating-assay-method for determination of diacerein in presence of degradation products

نویسندگان

  • Purnima Hamrapurkar
  • Priti Patil
  • Masti Desai
  • Mitesh Phale
  • Sandeep Pawar
چکیده

BACKGROUND To understand the degradation behavior of diacerein and to develop a simple, rapid, sensitive, and validated RP-HPLC method for the determination of diacerein, in the presence of its degradation products. MATERIALS AND METHODS An accurate, sensitive, precise, rapid, and isocratic reversed-phase high-performance liquid chromatography (RP-HPLC) method, equipped with a photo-diode array (PDA) detector for analysis of diacerein in the bulk drug has been developed and validated. The best separation was achieved on a 250 mm × 4.6 mm i.d., 5-μm particle, RP C18 column with 50 : 50 (v/v) of water (pH adjusted to 2.9 with orthophosphoric acid) : acetonitrile as the mobile phase, at a flow rate of 1.0 ml/minute. The detection wavelength was set at 257 nm. RESULTS The response was a linear function of concentration over the range of 0.50 - 20 μg/ml (r = 0.999) and the limits of detection and quantitation were 0.1 μg/ml and 0.50 μg/ml, respectively. The method was validated in accordance with the International Conference on Harmonization (ICH) guidelines. The drug was subjected to oxidative, hydrolytic, photolytic, and thermal stress. The drug decomposed under alkaline hydrolytic stress conditions and also on thermal degradation and photolysis. It was stable on acid hydrolysis and oxidation. The degradation products produced as a result of this stress did not interfere with the detection of diacerein, and the assay could thus be regarded as stability-indicating. CONCLUSION The method was suitable for application in the analysis of formulations of diacerein in quality-control laboratories, because it was simple and rapid, with good accuracy and precision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Stability-Indicating High Performance Liquid Chromatographic Method for the Determination of Diacerein in Capsules

A stability-indicating HPLC method was developed and validated for the quantitative determination of diacerein in capsule dosage forms. An isocratic separation was achieved using a perfectsil target ODS-3, 250x4.6 mm i.d., 5 microm particle size columns with a flow rate of 1 ml/min and using a UV detector to monitor the eluate at 254 nm. The mobile phase consisted of phosphate buffer:acetonitri...

متن کامل

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

Non-Aqueous Electromigration Analysis of Some Degradation Products of Carvedilol

A capillary electrophoresis method was used for assay of some degradation products of carvedilol. The optimized parameters were as; running buffer 80 mM acetate dissolved in methanol/ethanol mixture (65:35 v/v), applied voltage of 19 kV, temperature is 20 ºC and the wavelength range of 200-350 nm. The results indicate that the proposed CE method could effectively separate carvedilol from its de...

متن کامل

Non-Aqueous Electromigration Analysis of Some Degradation Products of Carvedilol

A capillary electrophoresis method was used for assay of some degradation products of carvedilol. The optimized parameters were as; running buffer 80 mM acetate dissolved in methanol/ethanol mixture (65:35 v/v), applied voltage of 19 kV, temperature is 20 ºC and the wavelength range of 200-350 nm. The results indicate that the proposed CE method could effectively separate carvedilol from its de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2011