Can a physical activity monitor provide a valid measure of arm elevation angle? A study to assess agreement between the SenseWear Mini Armband and the universal goniometer
نویسندگان
چکیده
BACKGROUND We undertook the current study to assess whether an accelerometer-based physical activity monitor, the SenseWear Mini Armband (SMA), could be used to provide data on static arm elevation, and to assess the agreement between static arm elevation measures obtained using SMA-derived data and those obtained with a universal goniometer. METHODS Using a universal goniometer, healthy adult subjects (n = 25, age 30 ± 9 years) had each of right and left arms positioned in a series of set positions between arm-by-side and maximal active arm flexion (anteversion), and arm-by-side and maximal active arm abduction. Subjects wore the SMA throughout positioning, and SMA accelerometer data was used to retrospectively calculate/derive arm elevation angle using a manufacturer-provided algorithm. The Bland-Altman method was used to assess agreement between goniometer-set and SMA-derived arm elevation angles. RESULTS There were significant differences between goniometer-set and SMA-derived arm elevation angles for elevation angles ≤ 30 degrees and ≥ 90 degrees (p < 0.05). Bland-Altman plots showed that the greater the angle of elevation, the greater the mean difference between goniometer-set and SMA-derived elevation angles. Adjustment of the manufacturer-provided algorithm for deriving arm elevation angle corrected for this systematic difference, and resulted in 95% limits of agreement ± 12 degrees (flexion) and ± 13 degrees (abduction) across the full range of arm elevation. CONCLUSIONS The SMA can be used to record data allowing derivation of static arm elevation angle in the upright position, 95% limits of agreement with the universal goniometer being similar to those reported for digital inclinometers and gyroscopes. Physiotherapists looking for innovative methods of recording upper limb range of motion should consider the potential of accelerometer-based physical activity monitors such as the SMA.
منابع مشابه
SenseWear Armband and Stroke: Validity of Energy Expenditure and Step Count Measurement during Walking
The purpose of this study was to test the validity of the SenseWear Pro Armband (SWA) for the measurement of energy expenditure (EE) and step count against a criterion in persons with stroke. Twelve participants with chronic stroke (mean age 64.2 ± 10.4 years; mean gait speed 0.67 ± 0.25 m/sec) completed two trials of a six-minute walk test, while wearing a SenseWear Armband (SWA) on each arm a...
متن کاملValidity and Usability of Low-Cost Accelerometers for Internet-Based Self-Monitoring of Physical Activity in Patients With Chronic Obstructive Pulmonary Disease
BACKGROUND The importance of regular physical activity for patients with chronic obstructive pulmonary disease (COPD) is well-established. However, many patients do not meet the recommended daily amount. Accelerometers might provide patients with the information needed to increase physical activity in daily life. OBJECTIVE Our objective was to assess the validity and usability of low-cost Int...
متن کاملMonitoring Energy Expenditure Using a Multi-Sensor Device—Applications and Limitations of the SenseWear Armband in Athletic Populations
In order to monitor their energy requirements, athletes may desire to assess energy expenditure (EE) during training and competition. Recent technological advances and increased customer interest have created a market for wearable devices that measure physiological variables and bodily movement over prolonged time periods and convert this information into EE data. This mini-review provides an o...
متن کاملAbstract -- The ability to accurately and reliably monitor physical activity and energy expenditure has emerged as a critical component to weight management and the prevention of lifestyle related health
The ability to accurately and reliably monitor physical activity and energy expenditure has emerged as a critical component to weight management and the prevention of lifestyle related health problems. Current methods and tools used by researchers, clinical practitioners, and individuals to assess physical activity and energy expenditure were reviewed and found to have practicality and accuracy...
متن کاملValidity of physical activity monitors for assessing lower intensity activity in adults
BACKGROUND Accelerometers can provide accurate estimates of moderate-to-vigorous physical activity (MVPA). However, one of the limitations of these instruments is the inability to capture light activity within an acceptable range of error. The purpose of the present study was to determine the validity of different activity monitors for estimating energy expenditure (EE) of light intensity, semi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2015